20mm inductive sensing, M18 threaded body, 10V ~ 30V supply, and -25°C ~ 70°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 20MM NPN M18 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
An Active M18 sensor, if the mounting gives it room
Unshielded mounting limits where metal can sit around the sensing face, but E2E-X20MC3L18-R 2M is Active and a reasonable new design-in where the machine can accommodate a threaded M18 inductive sensor. The thread alone proves no fit. Its 3-Wire NPN-NC/NO output needs an input wired for a sinking sensor; a sourcing-only input is the wrong match.
IP67 and IP69K address ingress at the sensor, not a poor electrical match or a missed target. EU RoHS is marked compliant. On an existing production line, retain the mounting and input assumptions already proven on the machine rather than taking the M18 thread as proof of fit.
The supply and target set different limits
Supply voltage is bounded: 10V at the low end, 30V at the ceiling. That span can rule a machine rail in or out, but it doesn't establish how much load the output can drive. The 20mm sensing distance calls for a check with the actual metal part, not an assumption that every target will be detected at 20mm.
A location outside the -25°C ~ 70°C operating-temperature range rules out the installation, even if the body threads into place.
Will the line accept cable leads?
Will the line accept cable leads instead of a connector? This M18 sensor has cable-lead termination and ships in a box. Check routing and termination before putting it on a running line; Active status does not resolve a wiring mismatch.
What 200Hz leaves unanswered
200Hz is the listed response frequency, not the timing of an individual output transition. For a target moving quickly past the sensing face, the missing response-time specification matters. Neither an output load-current rating nor a wiring pinout is given, so the input-circuit check can't be closed here. A mounting drawing is still needed to settle how the unshielded M18 body sits beside surrounding metal.
View the Win-Source product page for E2E-X20MC3L18-R 2M.
Key Takeaways for Engineers & Buyers
- Check the 20mm sensing distance against the actual metal target.
- Keep the supply within 10V ~ 30V; match the input to 3-Wire NPN-NC/NO.
- Route the cable leads for the -25°C ~ 70°C operating range.