Omron E2E-X20MD1 2M: Active, but hold design-in for RoHS

E2E-X20MD1 2M Omron product image

20mm sensing distance, 12V–30V supply bounds, M30 body; RoHS status conflicts.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors
PackageCylinder, Threaded - M30
Core functionSENSOR PROX
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NO, 2-Wire; Response Frequency: 100Hz; Voltage - Supply: 12V ~ 30V

Active lifecycle, disputed RoHS: a conditional design-in

Hold new design-in. Both the lifecycle and product-status fields mark E2E-X20MD1 2M Active, so the hold comes from conflicting compliance entries rather than a lifecycle restriction to sustaining designs. The compliance field says RoHS Compliant; the specification says RoHS Non-Compliant. Get a definitive EU RoHS declaration for this exact part before approving a regulated BOM.

The listed 12V to 30V supply bounds set the electrical interface, but cable drop still matters at the sensor. The -25°C to 70°C operating-temperature window defines the environment to evaluate; it doesn’t establish the temperature at the mounting point.

Can bulk cable leads enter this build?

Will bulk cable leads work in this build? Bulk packaging and cable leads are the listed configuration, not a plug-in termination. Put receiving and cable-termination steps for E2E-X20MD1 2M in the assembly instructions before committing it to a build that expects a mating connector. The threaded body may fit the fixture even when the electrical assembly cannot proceed.

Unshielded mounting needs room around the M30 body

Nearby metal is the weak point for unshielded construction, though the M30 threaded, nickel-plated brass cylinder gives the fixture a defined mounting format. IP67 is the listed ingress-protection rating and helps in choosing a machine location; it doesn’t establish how the cable termination behaves in a particular cleaning process. This mounted inductive sensor is not a drop-in for any sensor hole.

20mm sensing distance is not a target guarantee

20mm is the listed sensing distance, not a guarantee of detection at that separation for every metal target. Target material and unshielded mounting can determine whether the machine trips where the fixture drawing expects it. The 100Hz response frequency is a stated dynamic limit, but it does not establish the timing of the NO, 2-Wire output at the controller input. Those figures can rule out a requirement beyond the listing, not sign off a borderline installation.

What still blocks fixture and input sign-off?

And without a dimensioned mounting drawing, target-dependent sensing curves, and output load-current limits, fixture clearance and the controller-input interface remain open.

View the Win-Source product page for E2E-X20MD1 2M.

Key Takeaways for Engineers & Buyers

  • Resolve the conflicting RoHS flags before releasing E2E-X20MD1 2M to a regulated BOM.
  • Check target detection against the listed 20mm distance in the unshielded M30 mounting.
  • Specify bulk cable-lead termination in the assembly instructions.