Omron E2E-X20MD15L 2M: Active, with RoHS unresolved

E2E-X20MD15L 2M Omron product image

20mm sensing distance, 12V ~ 24V supply limits, M18 threaded body.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 20MM CYL
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NO, 2-Wire; Response Frequency: 100Hz; Voltage - Supply: 12V ~ 24V

Active status clears one hurdle, not the RoHS conflict

And that's only the lifecycle question. All lifecycle fields agree on Active, making new design-in reasonable on lifecycle grounds. The compliance field says RoHS Compliant; the specification field says RoHS Non-Compliant. Neither resolves the contradiction, so clear it before releasing E2E-X20MD15L 2M into a build requiring EU RoHS.

The sensing target and supply set the first boundaries

The 20mm sensing figure sets a target check, while the 12V ~ 24V supply limits set a rail check. The listed distance does not promise switching at 20mm for every metal target, and a supply within those limits says nothing about whether the NO, 2-wire output will work with the intended controller input. A sensor can detect its target and still fail to register at the controller.

Bulk packing changes how this sensor reaches the line

Bulk packing complicates line-side handling, though it is a defined packing format. Set a receiving and feeding method for bulk units before E2E-X20MD15L 2M goes on a running build.

An unshielded M18 body needs room at the sensing face

A flush sensor pocket won't suit an unshielded M18 threaded cylinder. A metal-target station with room around the sensing face is a better fit. The threaded body offers a starting geometry for the bracket, not the clearance needed to finish it.

The -25°C ~ 70°C operating range sets the ambient-temperature boundaries; it does not cover a location exposed to heat outside that range. IP67 rates the sensor for ingress, not the installed mating connection. Match the NO, 2-wire output to the controller input rather than assuming the existing wiring scheme will accept it.

100Hz leaves the switching details open

100Hz is the listed response frequency, but no response-time definition or switching waveform accompanies it. Without a target-material correction curve, the 20mm sensing entry cannot settle detection on the actual target. Get the connector pinout and mounting drawing before committing the harness or bracket.

View the Win-Source product page for E2E-X20MD15L 2M.

Key Takeaways for Engineers & Buyers

  • Resolve the conflicting RoHS entries before design-in release.
  • Check the actual target against the listed 20mm sensing distance.
  • Plan line-side handling for bulk-packed sensors.