20mm sensing limit, 100Hz response ceiling, M30 body, and -25°C ~ 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NC, 2-Wire; Response Frequency: 100Hz; Voltage - Supply: 12V ~ 30V |
Active status does not settle the RoHS conflict
The RoHS entries conflict: the compliance field says compliant, while the specification says non-compliant. Lifecycle status is clearer: all fields mark E2E-X20MD2 2M Active. An EU RoHS conformity claim remains blocked, so consider the sensor for a new inductive-sensing design or existing production line only with compliance approval held until the manufacturer resolves the contradiction.
Will bulk cable-lead sensors fit the build process?
Will bulk packaging work on this line? Bulk is the stated packaging, and cable leads require a termination step rather than a plug-in connection. Specify that termination in the assembly instructions before release.
The 20mm limit is not a guaranteed trip point
20mm is the listed sensing-distance limit. It isn't a guaranteed trip point against every metal target. Because the construction is unshielded, nearby metal and bracket geometry could change where detection occurs, so test the actual target at its installed spacing before fixing the mounting position.
Speed has a ceiling. The 100Hz response-frequency limit does not establish that every brief pass will register; check the moving target against the required detection timing. The 12V ~ 30V supply limits exclude rails outside that range, while the -25°C ~ 70°C operating range sets the installation's temperature boundary. E2E-X20MD2 2M belongs on the drawing only when target spacing, timing, supply, and installed temperature all clear those boundaries.
An unshielded M30 body needs room around the target
A tightly packed metal bracket is the wrong place to assume this unshielded sensor will retain its listed reach. A threaded M30 mounting point with room around the sensing face is a more plausible fit. Its NC, 2-wire output needs an input intended for that arrangement, rather than one expecting an isolated contact. IP67 describes the sensor’s ingress protection; it does not establish protection for a field splice on its cable leads.
Mounting and input details still need a datasheet
The 20mm limit leaves mounting clearance and switching behavior unresolved. No mounting-clearance drawing or target-material correction data is listed for the unshielded body; hysteresis and off-state leakage are absent too. Obtain those datasheet items before fixing the bracket and input circuit.
View the Win-Source product page for E2E-X20MD2 2M.
Key Takeaways for Engineers & Buyers
- Test 20mm detection against the actual metal target and mounting clearance.
- Check the moving target against the 100Hz response ceiling.
- Get manufacturer resolution of the conflicting RoHS entries before approval.