Omron E2E-X20MD2 5M: Active, but RoHS status conflicts

E2E-X20MD2 5M Omron product image

20mm inductive sensing, 12V ~ 24V supply, M30 threaded body, and -25°C ~ 70°C operation.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors
PackageCylinder, Threaded - M30
Core functionSENSOR PROX
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NC, 2-Wire; Response Frequency: 100Hz; Voltage - Supply: 12V ~ 24V

Active status clears lifecycle, not the RoHS conflict

Can this sensor go on a new BOM? Active appears in every listed lifecycle field for Omron E2E-X20MD2 5M, leaving new design-in and sustaining production open on lifecycle grounds while the conflicting RoHS declarations hold up a RoHS-controlled release. One field says RoHS Compliant; the specification says RoHS Non-Compliant. Don't release a RoHS-controlled build until that contradiction is resolved.

Bulk packaging changes assembly planning. Account for bulk receipt and cable-lead handling in the assembly instructions rather than assuming a presentation suited to automatic feeding. That handling decision is separate from the compliance hold.

A 100Hz response is wrong for faster event counting

If event counting needs a response faster than 100Hz, this isn't the sensor for it. It fits an M30 threaded mount where an unshielded inductive sensor and an NC, 2-wire output match the machine's input scheme.

The 20mm gap still depends on the target

20mm is the listed sensing distance, not a guaranteed switching gap for every target. Target material and mounting geometry decide whether the bracket works. The 12V ~ 24V supply range sets the rail boundary, but does not establish the output's allowable load.

The -25°C ~ 70°C operating-temperature range rules out placements beyond those bounds. IP67 describes the sensor's listed ingress protection, not the sealing of the far end of its cable.

The bracket and input circuit need missing limits

Release is blocked. The datasheet still has to supply a sensing-distance-versus-target curve, output load-current and residual-voltage limits, and a mounting drawing. Until then, the listed sensing distance cannot settle the bracket layout, and the NC, 2-wire description cannot settle the input circuit.

View the Win-Source product page for E2E-X20MD2 5M.

Key Takeaways for Engineers & Buyers

  • Hold RoHS-controlled release until the conflicting declarations are resolved.
  • Check the 100Hz response frequency against the event rate.
  • Check M30 mounting clearance for the unshielded 20mm sensing geometry.