Omron E2E-X22B1D30 2M: Active for new industrial designs

E2E-X22B1D30 2M Omron product image

22mm sensing distance, 10V–30V supply range and threaded M30 body; PNP-NO cable output.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 22MM PNP M30 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

Does the 22mm reach justify a new machine design?

22mm is the listed sensing distance, not guaranteed mounting clearance for every target. E2E-X22B1D30 2M is listed Active, so new design-in is reasonable if the intended target can be detected at its planned position. EU RoHS status is compliant.

The supply and target rate set different limits

And that reach matters only if the control system accepts a PNP-NO, 3-wire output. The listed 10V–30V supply range bounds the rail choice; 30V is a ceiling, not a preferred operating point. Compare the target rate with the 200Hz response-frequency ceiling, which doesn't establish switching behavior at that rate.

The -25°C to 70°C operating-temperature range limits where the sensor belongs. Outside it, IP67/IP69K ingress ratings and a nickel-plated brass body don't rescue the installation.

What remains unknown at the sensing face?

The gaps are real. No target-material response curve is listed, so 22mm alone cannot settle bracket placement for the actual target. Output load-current limits and a cable-lead pinout are absent; both are needed before control-input and wiring sign-off. A mechanical drawing is needed to settle mounting clearances.

Will the connection format match the running line?

Will the line accept cable leads rather than a connector? For this Active part, termination is a practical stop: the right sensing distance and PNP-NO output won't help if the machine expects a different connection. Put E2E-X22B1D30 2M on the order with its cable-lead termination and threaded M30 body, so the received configuration can be checked against the machine, not just the sensing function.

The package field says Box, not how much room the mount needs. On an existing production line, match the current wiring method and threaded mount before changing the BOM; for a new machine, do it before bracket fabrication. The listed format narrows the choice, but it does not specify cable conductors or the body's full geometry.

View the Win-Source product page for E2E-X22B1D30 2M.

Key Takeaways for Engineers & Buyers

  • Keep the supply within the listed 10V–30V range.
  • Compare the required target rate with the 200Hz response-frequency ceiling.
  • Check the intended target at the 22mm listed sensing distance before fixing the bracket.