22mm sensing distance, 10V ~ 30V supply limits, M30 body and -25°C ~ 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 22MM PNP M30 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
Active status clears the first hurdle for this PNP sensor
And lifecycle isn't the objection: E2E-X22B1D30 5M is marked Active throughout, with no conflicting status, and belongs on a new-design shortlist as well as an existing production BOM. Its PNP-NO, 3-wire output calls for a control input expecting a sourcing, normally open signal; a sinking input is not a direct fit. The part is EU RoHS compliant; no directive revision is stated.
The 22mm reach matters more than the M30 thread alone
The weak point is the 200Hz response frequency: it limits use with fast-moving targets, while the listed 22mm sensing distance gives the intended metal target and mounting position a concrete first check. That distance does not establish the switching gap for every target. The shielded, threaded M30 body provides a starting point for mechanical layout, but the installed geometry still matters.
The 10V ~ 30V supply limits rule out direct connection to a rail outside that range; a supply inside those limits does not settle the output-load budget. The -25°C ~ 70°C operating range sets the temperature envelope for placement. IP67 and IP69K describe the sensor’s ingress protection, not how its cable leads will be terminated in the machine.
M30 mounting leaves a cable-lead assembly decision
The M30 thread fixes the mounting constraint. Cable leads set the repeat-build step: define their routing and termination in the work instructions before releasing the sensor to a running line. A consistent mount won't prevent an inconsistent connection.
Wiring and target behavior still need drawings
Key details are missing. No wiring diagram or pinout is given, so PNP-NO, 3-wire does not identify which lead goes where. The mounting drawing and target-dependent sensing behavior are absent; both matter when judging the listed 22mm distance against the installed target. Without an output load-current limit, the control-input connection remains unresolved.
View the Win-Source product page for E2E-X22B1D30 5M.
Key Takeaways for Engineers & Buyers
- Check the 22mm sensing distance against the installed metal target.
- Keep the supply within the 10V ~ 30V limits.
- Specify cable-lead termination for the M30 assembly.