Omron E2E-X22B1D30 5M: Active for New Sensor Designs

E2E-X22B1D30 5M Omron product image

22mm sensing distance, 10V ~ 30V supply limits, M30 body and -25°C ~ 70°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 22MM PNP M30 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

Active status clears the first hurdle for this PNP sensor

And lifecycle isn't the objection: E2E-X22B1D30 5M is marked Active throughout, with no conflicting status, and belongs on a new-design shortlist as well as an existing production BOM. Its PNP-NO, 3-wire output calls for a control input expecting a sourcing, normally open signal; a sinking input is not a direct fit. The part is EU RoHS compliant; no directive revision is stated.

The 22mm reach matters more than the M30 thread alone

The weak point is the 200Hz response frequency: it limits use with fast-moving targets, while the listed 22mm sensing distance gives the intended metal target and mounting position a concrete first check. That distance does not establish the switching gap for every target. The shielded, threaded M30 body provides a starting point for mechanical layout, but the installed geometry still matters.

The 10V ~ 30V supply limits rule out direct connection to a rail outside that range; a supply inside those limits does not settle the output-load budget. The -25°C ~ 70°C operating range sets the temperature envelope for placement. IP67 and IP69K describe the sensor’s ingress protection, not how its cable leads will be terminated in the machine.

M30 mounting leaves a cable-lead assembly decision

The M30 thread fixes the mounting constraint. Cable leads set the repeat-build step: define their routing and termination in the work instructions before releasing the sensor to a running line. A consistent mount won't prevent an inconsistent connection.

Wiring and target behavior still need drawings

Key details are missing. No wiring diagram or pinout is given, so PNP-NO, 3-wire does not identify which lead goes where. The mounting drawing and target-dependent sensing behavior are absent; both matter when judging the listed 22mm distance against the installed target. Without an output load-current limit, the control-input connection remains unresolved.

View the Win-Source product page for E2E-X22B1D30 5M.

Key Takeaways for Engineers & Buyers

  • Check the 22mm sensing distance against the installed metal target.
  • Keep the supply within the 10V ~ 30V limits.
  • Specify cable-lead termination for the M30 assembly.