Omron E2E-X22B1D30-R 2M: Active for New Machine Builds

E2E-X22B1D30-R 2M Omron product image

22mm listed sensing distance, 10V ~ 30V supply limits, M30 body and PNP-NO cable leads.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 22MM PNP M30 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

Can this M30 sensor go into a new machine build?

Can I specify this for a new machine? Yes. E2E-X22B1D30-R 2M has Active lifecycle and product-status fields, with no stated conflict, so it remains an option for new design-in and existing production. Active status doesn't settle electrical or mounting fit. The part is listed as EU RoHS compliant.

Carry the cable-lead termination onto the harness drawing before release. Box describes the packaging, not a connector.

The 22mm gap and 200Hz limit constrain detection

Sensing distance and response frequency impose separate ceilings. The listed 22mm sensing distance does not establish detection at that gap for every metal target. The 200Hz response-frequency ceiling bounds the event rate but gives no switching delay for a moving target.

The listed 10V ~ 30V supply range sets the rail boundaries. Its 30V upper limit is a ceiling, not a preferred setpoint, and the range says nothing about how much load the PNP-NO output can drive.

The M30 body fits a metal-target station, not every input

It’s for metal-target stations. The shielded, threaded M30 cylinder needs a bracket that accepts the body, and its cable leads need a route back to the controller before the harness and mounting layout are fixed. The PNP-NO, 3-Wire output will not match an input specified for the opposite output polarity.

The listed IP67 and IP69K classifications support considering it where ingress protection matters, but they do not establish the sealing of the installed cable route or surrounding assembly. Its -25°C ~ 70°C operating-temperature range puts 70°C at the upper limit: an enclosure that exceeds it rules the sensor out even if the target geometry works. The LED can help check state locally; it does not establish switching delay.

The bracket and wiring still need missing details

And the build drawing still lacks two essentials: a dimensional drawing for bracket clearance and a cable-wire assignment for wiring. Output load-current limits and target-dependent sensing curves are also missing; they govern input drive and trigger gap.

View the Win-Source product page for E2E-X22B1D30-R 2M.

Key Takeaways for Engineers & Buyers

  • Set the bracket around the M30 threaded body; treat 22mm as the listed sensing ceiling.
  • Keep the supply within the listed 10V ~ 30V limits, not at 30V by default.
  • Match the PNP-NO, 3-Wire cable leads to the controller input.