22mm sensing distance, M30 threaded body and 10V ~ 30V supply range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 22MM PNP M30 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
Does the 22mm reach survive the actual target geometry?
22mm is the listed sensing distance for E2E-X22B1D30-R 5M, but the metal target must pass close enough to switch despite the travel set by the machine and the effects of target material and geometry. A fixture built around the full 22mm leaves no room for target variation. Establish the target and installation geometry before releasing the bracket; the listed distance is a screening number, not a signed-off trip point.
The shielded, threaded M30 body commits the bracket and guarding before electrical work starts. It won’t drop into a smaller bore after the metalwork is cut.
Can the active cable-lead version stay on the build?
Is this sensor still active for new builds? Its lifecycle signals agree on Active, supporting new design-in and continued production. EU RoHS compliance is listed.
The buying constraint is the boxed, cable-lead configuration. Specify the termination on the BOM and in the assembly instructions; a build arranged for a mating connector can’t accept these leads without a wiring-plan change.
Will the PNP-NO output match the controller?
The interface is specific. The supply must stay within 10V ~ 30V, with 30V as the ceiling. The PNP-NO, 3-wire output needs a controller input wired for that switching arrangement, not an NPN input assumed to behave the same way. Neither the supply range nor the output label establishes how much load current the sensor can switch.
Where do the M30 body and ingress ratings belong?
Machines outside the listed -25°C ~ 70°C operating-temperature range are wrong for this sensor, even if its M30 thread fits the bracket. At a fixed metal-target station exposed to water or cleaning, the listed IP67 and IP69K ingress ratings make the nickel-plated brass body worth considering. Those ratings address ingress, not resistance to the chemicals used in cleaning.
What does 200Hz leave unresolved?
200Hz is the listed response frequency, not a switching delay for a passing target. The missing target-dependent sensing curve and response timing leave detection unresolved; the wiring diagram and mounting drawing are needed to settle installation.
View the Win-Source product page for E2E-X22B1D30-R 5M.
Key Takeaways for Engineers & Buyers
- Set target travel against the listed 22mm sensing distance.
- Keep the supply within 10V ~ 30V; wire for the PNP-NO, 3-wire output.
- Put cable-lead termination in the build instructions.