22mm sensing distance; 10V ~ 30V supply; M30 threaded body; -25°C ~ 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 22MM PNP M30 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
PNP-NO rules out an NPN-only controller input
An NPN-only controller input is the wrong home for this inductive sensor. Its PNP-NO, 3-wire output needs a matching machine input; the shielded, threaded M30 body defines the mounting form, while cable leads require a wired harness termination. IP67 and IP69K are listed ingress ratings for the sensor. They don't settle how a field-made cable termination will be protected.
Active status supports a new M30 sensor installation
New design-in is reasonable. Active lifecycle signals agree for E2E-X22B1DL30 2M, and EU RoHS compliance is listed. Settle the cable-lead termination before releasing the assembly if the machine expects a connector.
The 22mm reach is a screen, not a guaranteed standoff
22mm is the listed sensing distance. It screens the required reach but does not establish the trip point for every target or mounting arrangement, so it cannot set the final sensor position on its own. The 10V ~ 30V supply limits rule out a direct connection to a rail outside that range; they say nothing about the output load the sensor can carry.
The 200Hz response-frequency ceiling does not establish detection of every passing target. That depends on the target and its motion through the sensing area. The -25°C ~ 70°C operating range bounds the stated temperature fit; operation outside it is not established here. A mounting point can meet the reach and supply limits yet still miss fast targets.
The M30 thread does not finish the installation drawing
The mounting drawing is missing, though the M30 thread gives panel layout a starting point. The lead wiring diagram and output load-current limit are absent too; those details determine the harness connections and whether the intended input load is permissible. Without the response test conditions behind 200Hz, detection timing remains unresolved.
View the Win-Source product page for E2E-X22B1DL30 2M.
Key Takeaways for Engineers & Buyers
- Match the controller input to the PNP-NO, 3-wire output of E2E-X22B1DL30 2M.
- Check target standoff against the listed 22mm sensing distance.
- Specify the cable-lead termination at the M30 mounting point.