22mm sensing distance, 200Hz response limit, M30 thread; 10V to 30V supply limits.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 22MM PNP M30 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
Active status clears the lifecycle gate, not the supply limits
The 10V lower and 30V upper supply limits set the first boundary: a machine rail outside them rules out this sensor before sensing distance matters. Omron E2E-X22B1T30 2M is a new-design candidate where the rail and its PNP-NO, 3-wire output match the controller input. All lifecycle signals say Active, with no conflict, and it is EU RoHS compliant. Neither status establishes whether it will detect the installed target.
200Hz matters only after the target sits within reach
Even with the rail settled, the sensor still has to see metal. The listed 22mm sensing distance is a reach to investigate, not a guaranteed trip point across target materials and mounting arrangements; treating it as one risks missed parts at the edge of detection. The 200Hz response frequency is a ceiling for counting, not a promise of clean transitions at that rate in the installed machine.
Mechanical fit comes next. The shielded M30 threaded body needs a bracket with room for that thread; an electrical match won't make it fit a smaller opening. The -25°C to 70°C operating-temperature range bounds the installation environment. A machine outside either end falls outside the stated fit, even if its targets move slowly enough for the response-frequency limit.
Cable leads make installation the buying constraint
Cable leads are a drawback on a line that routinely changes sensors: a technician must remake the termination rather than disconnect a plug. IP67 and IP69K ingress protection make the nickel-plated brass, M30 body plausible around washdown equipment, but those codes do not establish protection for the finished cable termination. Put cable routing and termination in the build instructions before committing Omron E2E-X22B1T30 2M to repeat builds.
What does the 22mm claim leave unresolved?
22mm leaves the actual target unqualified. Target-material correction and a mounting drawing are absent. So are a wiring diagram and an output load-current limit; PNP-NO alone doesn't settle controller wiring or permissible load.
View the Win-Source product page for E2E-X22B1T30 2M.
Key Takeaways for Engineers & Buyers
- Match the controller rail to the 10V and 30V supply limits.
- Check the 22mm sensing distance against the installed target.
- Compare the required event rate with the 200Hz response-frequency limit.