22mm sensing distance, 10V ~ 30V supply bounds, M30 body and -25°C to 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 22MM PNP M30 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new M30 installation
10V to 30V defines the listed supply bounds, but a rail inside that range only clears the electrical supply check; it says nothing about target detection. Omron lists E2E-X22B230 2M as Active across its lifecycle fields, with no conflict, supporting new design-in where the sensing geometry and electrical interface fit. EU RoHS compliance is stated without a revision. Define the cable-lead termination in the harness build before releasing the line.
PNP-NC rules out the wrong controller input
Wrong for a controller expecting NPN or normally open logic. The PNP-NC, 3-wire output needs an input that accepts a sourcing sensor and normally closed operation; the opposite arrangement can report the wrong machine state. This inductive sensor needs a metal target.
The 22mm reach sets the target geometry
22mm is the listed sensing-distance ceiling. If the target cannot come within that reach, the M30 threaded body will not rescue the layout. It isn't a promise of detection at 22mm for every target: material and mounting conditions still matter.
The listed 200Hz response frequency limits how quickly features can be presented; it is not a response-delay figure for the machine sequence. The -25°C to 70°C operating range rules out sensor locations outside those bounds. IP67 and IP69K are stated ingress-protection ratings, not ratings for the cable termination the machine builder adds.
The M30 thread does not finish the bracket or wiring
That leaves the bracket and wiring exposed. The datasheet must supply an outline drawing, sensing-distance test conditions, an output load-current limit and cable-lead wiring identification. M30 alone doesn't establish body clearance without the drawing; the remaining details leave target placement and the controller connection open.
View the Win-Source product page for E2E-X22B230 2M.
Key Takeaways for Engineers & Buyers
- Match the control rail to the 10V ~ 30V supply bounds.
- Check target travel against the listed 22mm sensing distance.
- Define the cable-lead termination before releasing the harness.