22mm sensing distance, 10V–30V supply limits, M30 threaded body, and PNP-NC output.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 22MM PNP M30 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
The 22mm sensing distance makes target placement the first decision
22mm is the listed sensing distance for E2E-X22B230 5M. That figure alone does not establish reliable clearance to a particular target in a particular mount, so settle the target geometry before fixing the M30 mounting position. If the sensor misses the target, electrical fit cannot keep the line running.
The listed 30V supply limit is a ceiling, not a preferred rail; 10V is the lower boundary. Those limits screen the sensor feed but leave wiring and input loading unresolved. Operating temperature spans -25°C to 70°C, with 70°C the upper boundary; temperature at the mount still matters. The lifecycle fields agree on Active, supporting new design-in. EU RoHS compliance is stated, but no directive revision or exemption is specified.
PNP-NC logic rules out the wrong controller input
An NPN or normally open controller input is the wrong mate. This inductive sensor has a PNP-NC, 3-wire output; match the controller logic before fixing the mounting hole. Its shielded M30 threaded body is nickel-plated brass and belongs in a threaded machine mount, not on a board footprint. Leave room to route the cable leads. IP67 and IP69K are listed ingress ratings, but they do not settle protection for the installed cable connection.
The 200Hz figure cannot settle switching timing
200Hz is the listed response-frequency ceiling. It can rule out target events that demand a faster response, but it won't tell you the switching delay at the controller input. No on/off timing, output-current rating, wiring diagram or mounting drawing is listed. Input loading and the installed layout remain open.
Cable leads need a repeatable plan on a running line
Cable leads complicate a running-line change compared with a connectorized sensor. Active status still supports keeping E2E-X22B230 5M in consideration for existing production; standardize cable routing before a change is needed. Box describes packaging, not an installation accessory.
View the Win-Source product page for E2E-X22B230 5M.
Key Takeaways for Engineers & Buyers
- Check the 22mm sensing distance against the target before fixing the M30 mount.
- Keep the sensor feed within the listed 10V–30V supply limits.
- Set the controller input for PNP-NC, 3-wire operation.