22mm sensing ceiling, 10V to 30V supply limits, M30 body and -25°C to 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 22MM PNP M30 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
The 22mm sensing ceiling makes target placement decisive
22mm is the listed sensing-distance ceiling. It isn't a promise for every target. Omron E2E-X22B3D30 2M is Active across the lifecycle fields, making new design-in reasonable where an inductive PNP sensor fits; EU RoHS compliance is listed. Check the target before release if the mount depends on detection at that ceiling.
200Hz does not settle detection on a moving line
200Hz is the listed response-frequency ceiling, not a guaranteed count rate for every moving target. Check timing against the metal target's time in the sensing zone. The supply must stay within 10V to 30V; 30V is the ceiling, not a nominal operating point. The PNP-NC/NO, 3-Wire output must also match the controller input. Supply voltage alone does not settle that connection.
The M30 mount fits only if the cable route does too
And that electrical match is only half the installation problem. The M30 threaded, shielded cylinder needs a machine bracket that brings its sensing face near the metal target, because a bracket built around a more distant pass risks missed detections. Cable leads put the termination in the machine wiring plan rather than on a connector at the sensor body.
The -25°C to 70°C operating-temperature range bounds the mounting environment. IP67 and IP69K are listed for the sensor, but they do not settle protection for the installed cable termination. The nickel-plated brass body suits a threaded metal mount; none of those construction details establishes detection distance for a particular target material or size.
The M30 envelope is known; the release details are not
The missing installation drawing is the weak point; M30 and cable leads still establish the mounting and wiring approach. Output-load current, switching hysteresis and cable conductor assignments are also absent from the listing. Input loading remains open, as do repeatability at a tight trip point and wire assignment. Get the drawing and those electrical details before releasing the bracket or wiring instructions.
Can the running line terminate cable leads?
Can the running line terminate cable leads? Box packaging does not change the assembly constraint: E2E-X22B3D30 2M needs a line-side termination step. Put cable preparation and termination into the assembly instructions before using it on an existing build. An M30 mechanical fit alone won't preserve the wiring operation.
View the Win-Source product page for E2E-X22B3D30 2M.
Key Takeaways for Engineers & Buyers
- Check target detection against the 22mm sensing ceiling in the chosen M30 mount.
- Keep the supply within 10V to 30V and match the PNP output to the input circuit.
- Add cable-lead termination to the line instructions before release.