22mm sensing distance, 10V ~ 30V supply and M30 body set the fit checks.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 22MM PNP M30 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
Cable leads complicate an otherwise viable design-in
Cable leads demand a wiring plan. E2E-X22B3D30 5M is Active across the stated lifecycle fields, making new design-in reasonable for a PNP industrial sensing point if the installation fits. EU RoHS compliance is listed.
The supply rail and event rate set firm boundaries
Supply and switching limits set the boundaries. The 10V ~ 30V supply range rules out a rail beyond either endpoint; the 30V upper bound leaves no allowance for supply spikes. The 200Hz response frequency is a switching-rate ceiling, not a promise that every passing target will be detected at that rate.
The -25°C ~ 70°C operating-temperature range excludes locations beyond its endpoints. It does not, by itself, settle the temperature at the mounted sensor.
A 22mm reach still needs a real target gap
22mm is the listed inductive sensing distance, not a guaranteed trip point for every metal target. A shielded M30 threaded cylinder belongs in a bracketed machine position where the target passes within the usable sensing gap and the cable leads can reach a PNP, 3-wire input without a field connector. A controller expecting another output topology rules it out. IP67 and IP69K describe the sensor’s ingress protection, not how the cable termination will be protected after installation.
Cable routing must be settled before release
So the cable route belongs on the purchase specification before release for existing production: E2E-X22B3D30 5M has cable leads, not a specified plug-in termination.
No wiring diagram, mounting drawing, target-material correction curve or output load-current limit is given. Obtain those details to settle the input connections and bracket clearance. The correction curve is needed to settle the detection gap; the load-current limit is needed to determine whether the PNP output can drive the intended input. The 22mm figure can't settle those decisions alone.
View the Win-Source product page for E2E-X22B3D30 5M.
Key Takeaways for Engineers & Buyers
- Keep the supply inside 10V ~ 30V; don't count on 30V for spike headroom.
- Check the target gap against the listed 22mm sensing distance.
- Compare the event rate with the 200Hz response-frequency ceiling.