22mm sensing distance and 200Hz response in an M30 body; 10V to 30V supply limits.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 22MM PNP M30 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
The M30 head belongs on a PNP input
It’s wrong for an NPN input or a mount that cannot take an M30 threaded body. E2E-X22B3D30-M1 is a shielded inductive sensor with a 3-wire PNP-NC/NO output; use it where the controller input and mechanical interface match.
Can this stay on a running line?
Can this remain in an existing build? Yes. E2E-X22B3D30-M1 has aligned Active lifecycle signals, supporting new design-in and existing production. EU RoHS compliance is stated. Specify the mating interface on the machine BOM: the sensor has a connector termination, and “Box” describes the package without establishing whether a mating cable is included.
22mm sensing does not settle target position
22mm is the listed sensing-distance ceiling, not a guaranteed trip point for every metal target. It gives the mounting decision a starting limit, not a finished tolerance. The 200Hz response-frequency ceiling rules out events beyond that rate, but it doesn’t settle machine timing on its own. Supply limits of 10V to 30V exclude a controller supply outside that range; neither endpoint is a recommended setpoint. The -25°C to 70°C operating temperature range sets the stated environmental bounds, so account for local heating in the installation.
The connector and target still need answers
That leaves the wiring unresolved. The connector pinout is absent, so the 3-wire PNP-NC/NO description cannot tell a technician which contact goes to each circuit connection. A wrong assumption could leave the machine blind even when the sensor switches. The mating-connector drawing is absent too: an M30 mounting fit does not establish cable clearance or connector engagement.
Target-material correction data is missing, so the 22mm ceiling cannot close trip-position tolerance for a particular target. The output load-current limit is also absent; obtain that datasheet rating before committing the connected input or load. Those are circuit and installation decisions, not details the listed sensing distance can answer.
View the Win-Source product page for E2E-X22B3D30-M1.
Key Takeaways for Engineers & Buyers
- Check target position against the 22mm listed sensing distance.
- Match the controller input to the 3-wire PNP-NC/NO output.
- Get the connector pinout before releasing the mating-cable BOM.