22mm sensing distance, 10V–30V supply limits, M30 thread and -25°C to 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 22MM PNP M30 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
Is this M30 sensor a new-build choice?
Can I put this sensor on a new machine BOM? Yes. The lifecycle fields for E2E-X22B3D30-R 2M agree on Active status, with no stated end-of-life obstacle to design-in. EU RoHS compliance is also listed. Neither point settles the installation.
The cable leads still need a route and termination before build instructions are released; box packaging doesn't settle either detail. For existing production, keep the cable-lead termination arrangement consistent across builds rather than assuming the M30 threaded body alone makes the sensor a drop-in fit.
The 22mm reach sets the target geometry
22mm is the listed sensing distance. It sets the first check on target placement, not a guarantee of detection for every target material or mounting condition. The M30 threaded, shielded body needs a matching machine bracket, not a smaller opening chosen solely for sensing reach.
The 10V–30V supply limits bound the rail choice; 30V is a ceiling, not a setpoint. The 200Hz response-frequency figure helps screen target speed but provides no switching waveforms for a close timing call.
Cable leads complicate an exposed machine station
Cable leads complicate service replacement, but the nickel-plated brass body and listed IP67/IP69K ingress ratings support use at an exposed machine station. Those ratings don't establish protection for the finished cable termination.
The stated -25°C to 70°C operating-temperature range allows a direct check against machine ambient conditions. Outside that range, the listing gives no operating basis for the sensor.
What still blocks the installation drawing?
Installation details remain open. The listing has no mechanical drawing or cable-lead wiring diagram; both are needed to release bracket and termination details. A sensing-distance curve by target material is also missing, so the 22mm figure alone cannot close target selection.
View the Win-Source product page for E2E-X22B3D30-R 2M.
Key Takeaways for Engineers & Buyers
- Check the 22mm sensing distance against the target position.
- Keep the supply within the listed 10V–30V limits.