22mm listed sensing distance, 10V to 30V supply bounds, M30 threaded body, and -25°C to 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 22MM PNP M30 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
A 22mm sensing distance is not guaranteed clearance
Target clearance is the first constraint. The listed 22mm sensing distance does not guarantee a switch at that standoff; target travel must bring the metal into a validated detection zone before the mounting position can be fixed. The control rail must stay within the 10V to 30V supply bounds, with 30V treated as a ceiling rather than a setpoint. That range says nothing about permissible output load. The listed 200Hz response frequency sets a speed ceiling for event detection but does not establish switching behavior for the machine’s actual target. A marginal target can produce missed counts.
Can this active Omron sensor go on a new machine BOM?
Can it go on a new machine BOM? Yes. E2E-X22B3D30-R 5M is Active in both lifecycle and product-status fields, with no stated conflict, and is marked EU RoHS compliant. Specify cable-lead termination; the installation must accept wired leads rather than assume a connector.
M30 mounting makes the target path decisive
That BOM choice still has to fit the machine. The shielded, threaded M30 body needs a mount that brings a metal target through its sensing zone; it cannot fix a layout where the target never comes within the listed 22mm distance. The -25°C to 70°C operating range sets the installation’s temperature bounds. IP67 and IP69K are listed ingress ratings, not evidence that the cable exit or surrounding machine assembly has the same protection.
The M30 drawing and output wiring still matter
The wiring isn't settled. No wiring diagram is given: PNP-NC/NO, 3-wire identifies the output arrangement but not the lead assignments or how the stated contact behavior is wired. No output-load rating is given either, so the 10V to 30V supply bounds cannot establish whether the intended input and attached load suit the sensor output.
The M30 threaded cylinder needs a dimensional drawing before mounting depth and cable-exit clearance can be fixed. Sensing-distance curves for target material and geometry are also absent; the listed 22mm distance alone cannot establish the switching position for a particular metal flag. Settle those points before releasing the machine drawing.
View the Win-Source product page for E2E-X22B3D30-R 5M.
Key Takeaways for Engineers & Buyers
- Test target travel against the listed 22mm sensing distance.
- Keep the control supply within the 10V to 30V bounds.
- Put M30 mounting and cable leads on the machine drawing.