Omron E2E-X22C130-R 5M: Active for New Designs

E2E-X22C130-R 5M Omron product image

22mm listed sensing distance, 10V ~ 30V supply and M30 threaded body; target behavior still needs checking.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 22MM NPN M30 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

Active status supports a new M30 installation

This is a new-design candidate. E2E-X22C130-R 5M has matching Active lifecycle and product-status entries, with no listed conflict. EU RoHS compliance is listed too.

The physical constraint comes next: this is a boxed sensor with cable leads, not a connector-ended unit. Plan the cable route before committing it to a running line.

The 22mm sensing ceiling is not a target guarantee

The 22mm sensing-distance ceiling is the weak point: it marks the reach worth testing, not a guaranteed switching point for the proposed target. By contrast, the 10V ~ 30V supply range gives a firm selection boundary. A cabinet rail outside that range rules the sensor out, while a rail inside it still leaves the output load-current limit unknown and the input assignment unresolved.

The -25°C ~ 70°C operating-temperature range sets the environmental boundary. It doesn't settle what happens at the sensing face when the target, mounting metal or temperature changes. Keep the proposed target and mounting geometry in the test plan rather than treating the listed distance as a guaranteed trip point.

M30 mounting and NPN-NO wiring decide the fit

The M30 mount and 3-Wire output constrain the bracket and input circuit. The threaded body needs a matching mount, and the NPN-NO output needs an input arranged for that signaling. Get either wrong and the sensor will not fit as planned.

Shielding and IP67, IP69K ingress ratings make it an industrial, board-external sensor candidate rather than a bare sensing element. The cable leads still need a route through the machine; the ingress ratings do not define one.

200Hz does not close the switching review

200Hz is the listed response frequency, not a switching waveform or an actuation-time guarantee. Switching hysteresis, the output load-current limit and a connection diagram are absent; get those details before fixing input timing and wiring.

View the Win-Source product page for E2E-X22C130-R 5M.

Key Takeaways for Engineers & Buyers

  • Match the 10V ~ 30V supply range to the cabinet rail.
  • Check the M30 threaded body against the machine bracket.
  • Get the output load-current limit before assigning the NPN-NO input.