Omron E2E-X22C2L30-M1: Active for New Sensor Designs

E2E-X22C2L30-M1 Omron product image

22mm sensing reach, 10V to 30V supply limits, M30 thread and -25°C to 70°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 22MM NPN M30 NC
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

Can this M30 sensor go on a new production BOM?

Can this sensor go on a new production BOM? E2E-X22C2L30-M1 is Active in both lifecycle and product-status fields, with no conflicting signal calling for sustaining-only use. EU RoHS compliance is listed without a directive revision.

The connector termination is the buying snag. Put the mating connector on the harness BOM before release; “connector” alone does not identify the connection the assembly must make.

The 22mm reach and 200Hz ceiling set different limits

Reach and event rate set separate limits. The listed 22mm sensing distance is a reach ceiling, not a gap at which every target is guaranteed to switch; the figures don't support detection beyond that ceiling. The 200Hz response-frequency ceiling limits the event rate under consideration but does not specify switching delay.

Supply limits run from 10V to a 30V ceiling, so the intended rail must stay within that window. The NPN-NC, 3-Wire output must also match the controller input; sensing reach cannot fix a logic mismatch.

M30 mounting suits the fixture, not every controller

M30 needs a matching fixture. The nickel-plated brass body has an M30 thread and shielded inductive sensing; a smaller mounting hole will not take it. IP67 and IP69K are listed ingress ratings for the sensor, not proof of a sealed mating connection. The -25°C to 70°C operating-temperature range rules out a hotter mounting position.

What the 22mm figure cannot settle

22mm can't qualify a target on its own. The datasheet still needs to supply target-material test conditions, switching hysteresis, the connector pinout and a mechanical drawing. Without those details, target clearance and the harness interface remain open.

View the Win-Source product page for E2E-X22C2L30-M1.

Key Takeaways for Engineers & Buyers

  • Keep the target gap within the listed 22mm sensing-distance ceiling.
  • Match the NPN-NC, 3-Wire output to the controller input before releasing the BOM.
  • Identify the mating connector before releasing the harness for production.