Omron E2E-X22C330 2M: Active for New Machine Designs

E2E-X22C330 2M Omron product image

22mm sensing distance, 10V–30V supply limits, M30 body, and -25°C to 70°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 22MM NPN M30 NO/NC
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

Can this M30 sensor go on a new machine BOM?

Can this sensor go on a new machine BOM? E2E-X22C330 2M is Active according to the lifecycle signals, and EU RoHS compliance is listed. That's enough to settle lifecycle status, not target detection or machine fit.

Cable leads are the assembly constraint. Put their termination in the work instruction rather than assuming a plug-in connection; that mistake changes how the machine is wired.

The 22mm distance sets the mounting decision

22mm is the listed sensing-distance limit, not a guaranteed switching gap for every target. Test the intended target before fixing the M30 mount at the edge of that distance; target-dependent detection remains unproven here.

The 10V–30V supply limits bound the rail choice, with 30V as a ceiling rather than a working setpoint. Neither the distance nor the voltage limits establish the output load the sensor can drive.

M30 mounting still has to match the input and enclosure

The M30 mount and 3-wire NPN output set separate fit constraints. The NPN-NC/NO designation belongs with an NPN-compatible input, not a PNP-only one. A shielded, nickel-plated brass body suits a threaded machine mount, but those construction details do not settle mounting geometry.

The -25°C to 70°C operating range bounds the stated environment. Outside it, this listing gives no basis for reliable detection. IP67 and IP69K are listed ingress ratings, useful when the sensor body faces washdown or contamination, but they do not establish how the cable termination is sealed in the finished machine. This mounted industrial sensor is not a substitute for a complete enclosure plan.

200Hz does not close the timing or wiring questions

200Hz is the listed response-frequency limit, not a switching-time waveform. Before fixing the input circuit and mount, get the missing cable wiring diagram and mounting drawing. The target-dependent sensing data and output load limit are also needed to establish whether the sensor can be positioned and connected as intended.

View the Win-Source product page for E2E-X22C330 2M.

Key Takeaways for Engineers & Buyers

  • Test the intended target before fixing the mount around the listed 22mm sensing distance.
  • Keep the sensor supply within the listed 10V–30V limits.
  • Compare the machine's event rate with the listed 200Hz response-frequency limit.