22mm listed sensing distance, M30 body, 10V ~ 30V supply, -25°C ~ 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 22MM NPN M30 NO/NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
The M30 mount is the first gate for this active sensor
The first constraint is fit: the M30 thread needs a matching opening, while the 22mm listed sensing distance puts the target gap on the screening list. E2E-X22C3L30 2M suits new design-in when those conditions and its NPN-NC/NO, 3-Wire output fit the machine. The active lifecycle signals agree, with no status conflict limiting it to sustaining-only use. It is EU RoHS compliant.
A 22mm sensing distance cannot settle the trigger gap alone
The weak point is the 22mm listed sensing distance: it screens a target gap but cannot establish where a particular metal target switches. That isn't a switching guarantee. The M30 threaded cylinder gives the fixture designer a definite mounting interface; if the opening differs, the fixture must change rather than a sensor setting.
The 10V ~ 30V supply range makes 30V a ceiling, not a recommended rail, and rules out a direct hookup to a machine bus outside that range even when the barrel fits. The -25°C ~ 70°C operating range screens installation temperature, but leaves the effect of temperature on switching distance unresolved.
Metal targets, not general object detection
Nonmetal targets are out: this is an inductive sensor. For metal targets in a threaded machine fixture, the shielded body and IP67/IP69K ingress ratings merit attention where exposure is part of the installation. Those ratings don't establish chemical compatibility for the nickel-plated brass body.
Can the line build accommodate cable leads?
Will the line take cable leads, or does it require a connector? E2E-X22C3L30 2M is boxed and uses cable-lead termination, so a connector-based build needs a defined termination step. Put that step in the build instructions, and check cable routing at the M30 fixture before releasing the assembly.
The drawing and switching detail still have to close the fit
And the fixture check still needs a dimensioned drawing: M30 alone gives neither body length nor cable-exit geometry. The wiring diagram has to settle the NPN-NC/NO, 3-Wire connections; target-dependent sensing information has to establish a usable switching gap. None of those details is listed here.
View the Win-Source product page for E2E-X22C3L30 2M.
Key Takeaways for Engineers & Buyers
- Check the M30 thread against the fixture opening.
- Screen the control input for NPN-NC/NO, 3-Wire operation.
- Add cable-lead termination to the line build instructions.