Omron E2E-X22C3L30 5M: Active for new designs

E2E-X22C3L30 5M Omron product image

22mm sensing distance, M30 threaded body, 10V to 30V supply bounds, -25°C to 70°C operation.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 22MM NPN M30 NO/NC
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

Active status supports a new M30 sensor position

So E2E-X22C3L30 5M belongs on the new-design shortlist if the machine calls for this sensing arrangement. Lifecycle signals agree on Active, and EU RoHS compliance is listed. The M30 threaded body and cable leads still have to fit the mounting point and wiring route before release.

Nonmetal targets and incompatible inputs rule it out

A nonmetal target rules out this inductive sensor. For metal targets, its shielded M30 body supplies the mechanical starting point, but the listed NPN-NC/NO, 3-wire output needs a compatible machine input; otherwise, the sensor can switch without the controller seeing the intended state.

The 10V to 30V supply bounds must contain the machine rail; they say nothing about excursions beyond that range. The -25°C to 70°C operating-temperature range is the stated environmental window, not a reason to ignore heat at the mounting point. IP67 and IP69K are listed, but neither settles cable routing.

22mm is the target-distance screening figure

22mm is the listed sensing distance, not a guaranteed trip point for every metal target. Check the actual target and mounting gap before fixing the bracket. The listed 200Hz response frequency screens event rate; it doesn't give a switching-delay figure.

Cable leads make wiring detail the release constraint

The missing connection detail is the weak point. The listed NPN-NC/NO, 3-wire output identifies the input arrangement, but a pinout is still needed to assign the cable leads, and a dimensioned drawing is needed before fixing the M30 mounting position. Switching-delay data and target-dependent sensing data are also absent; neither can be inferred from 200Hz or 22mm.

Cable leads are a practical buying constraint for an existing production line as well as a new build. Set the termination and cable route before release, rather than discovering at assembly that the planned connector or mounting clearance doesn't match the sensor.

View the Win-Source product page for E2E-X22C3L30 5M.

Key Takeaways for Engineers & Buyers

  • Test the 22mm sensing distance against the intended target.
  • Keep the machine rail within the listed 10V to 30V supply bounds.
  • Reserve space for the M30 body and a cable-lead route.