Omron E2E-X23B1D30-R 5M: Active for New Designs

E2E-X23B1D30-R 5M Omron product image

23mm sensing ceiling, 10V ~ 30V supply range, M30 body, -25°C ~ 70°C operating range

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 23MM PNP M30 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

Active status supports a new M30 sensor build

Is this sensor ready for a new machine BOM? E2E-X23B1D30-R 5M is Active across the listed lifecycle signals, with no conflict recorded, making it a new-design candidate rather than a sustaining-only purchase. EU RoHS compliance is recorded.

The physical details need attention before release. The listed package is a box, and termination is by cable leads rather than a connector. Put the cable route and termination method in the assembly instructions, and reserve an M30 threaded mounting location; without that space, an otherwise acceptable sensor becomes a mechanical rework job.

The supply window and switching rate set the controller boundary

The 10V ~ 30V supply range sets the controller boundary. Treat 30V as a ceiling, not a working target; a rail outside the range rules out a straightforward connection. The PNP-NO, 3-Wire output also needs a compatible input, or the machine has no usable sensor indication.

The listed 200Hz response frequency is a ceiling for the event-rate decision, not proof of timing at every target spacing. A machine that needs faster detection cannot be cleared on this rating.

23mm reach needs a real mounting position

23mm is the listed sensing-distance ceiling. Place the target within that limit rather than using it as a mounting gap to aim for. The shielded, M30 threaded body needs a rigid machine mounting point; it won't solve a bracket that cannot accept the thread.

IP67 and IP69K ingress ratings support selection where those protection classes are required, but they don't settle chemical compatibility for the nickel-plated brass body. The -25°C ~ 70°C operating-temperature range sets the ambient boundary. Outside it, the rating does not support the installation.

The M30 mounting drawing still matters

M30 fit remains unproven. Get the mounting drawing and cable-lead pinout before cutting the bracket or wiring the input. The output load-current limit is absent, leaving input loading unresolved; without sensing-distance dependence on target material, the actual detection gap is also unsettled.

View the Win-Source product page for E2E-X23B1D30-R 5M.

Key Takeaways for Engineers & Buyers

  • Match the machine input to PNP-NO, 3-Wire output.
  • Check the supply against 10V ~ 30V; treat 30V as the upper limit.
  • Reserve an M30 threaded mount and a route for the cable leads.