23mm sensing distance, M30 body, 10V ~ 30V supply, and -25°C ~ 70°C operation.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 23MM PNP M30 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

A PNP-NO sensor will not suit every controller input

An NPN controller input won't accept this PNP-NO, 3-Wire sensor. For a machine built around a PNP input, E2E-X23B1DL30 5M offers inductive sensing in a shielded M30 threaded body, with cable leads that belong in the machine wiring plan. The listed 23mm sensing distance gives the mount a starting position, not a proven detection gap for the actual target.

Can this M30 sensor go on a new machine BOM?

Can it go on a new machine BOM? Yes. E2E-X23B1DL30 5M is marked Active in both lifecycle and product-status fields, with no conflict between them. That status does not restrict it to sustaining designs. It comes in a box rather than a board-assembly format, so plan for cable-lead installation at the machine. EU RoHS compliance is listed.

The supply and switching limits set the installation boundary

Active status settles the BOM question, not the installation limits. The supply must stay within 10V ~ 30V: 30V is the ceiling, while a supply below 10V calls for a different choice. The 200Hz response-frequency figure is also a ceiling, not a guaranteed switching time. Examine a faster-moving target pattern before committing the sensor.

The stated operating-temperature range is -25°C ~ 70°C. A location outside either end falls outside that range, regardless of the IP67 and IP69K ingress-protection listings. Those ratings help assess enclosure exposure; they do not extend the temperature range or establish how the intended target will behave at the proposed sensing gap.

The 23mm target position still needs a physical trial

Target-material correction data is absent. The listed 23mm sensing distance still gives a physical trial its starting position. A mounting drawing and cable-wire assignment are also absent; obtain both before fixing the bracket or wiring the controller input.

View the Win-Source product page for E2E-X23B1DL30 5M.

Key Takeaways for Engineers & Buyers

  • Match the controller input to the PNP-NO, 3-Wire output.
  • Keep the supply within the listed 10V ~ 30V limits.
  • Trial the intended target before fixing the M30 mount at 23mm.