23mm sensing distance, 200Hz response ceiling, M30 thread, 10V to 30V supply limits.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 23MM PNP M30 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
Active status clears the lifecycle objection, not the sensing test
The 23mm sensing distance leaves target detection to be tested. E2E-X23B1T30 2M is Active across the lifecycle signals, supporting new design-in. EU RoHS compliance is listed.
The 23mm claim needs a real target
23mm is the listed sensing distance for this inductive sensor. Layout starts there. The shielded construction identifies the intended mounting approach, but neither it nor the listed distance establishes where the sensor will switch beside neighboring metal on the actual workpiece.
The 200Hz response frequency is a ceiling, not proof that every target will be detected at that rate. If the machine depends on closely spaced events, test detection under its actual motion.
The supply and temperature limits bound the installation
30V is the supply ceiling; 10V is the listed lower limit. A control supply outside those limits rules out a direct connection. The -25°C to 70°C operating-temperature range bounds the installation but does not establish the temperature at the sensor in a running machine.
The PNP-NO, 3-wire output needs an input built for that switching arrangement. A correct sensing distance won't fix an incompatible input.
Cable leads determine the assembly step
Will cable leads fit the line’s termination process? E2E-X23B1T30 2M is listed with cable leads and boxed packaging, not a connector at the sensor. Put lead termination in the assembly instructions before releasing the BOM. The box designation describes packaging, not how the leads connect in the machine.
The M30 thread does not finish the installation
That assembly choice still leaves the installed geometry open. The M30 threaded, nickel-plated brass body gives the mounting concept a starting point, but the missing mounting drawing must settle insertion depth and clearance around nearby metal. The listed IP67 and IP69K ratings describe ingress protection; they do not establish how the finished lead termination performs in the installed assembly.
The datasheet still needs to supply a wiring diagram and an output load-current limit before the PNP-NO input circuit can be closed. A target-material correction curve is also absent here. Without it, the 23mm sensing distance cannot establish detection margin on the actual workpiece.
View the Win-Source product page for E2E-X23B1T30 2M.
Key Takeaways for Engineers & Buyers
- Test the 23mm sensing distance against the actual target.
- Keep the sensor supply within the listed 10V to 30V limits.
- Plan the cable-lead termination before releasing the M30 installation.