10V ~ 30V supply, 23mm sensing distance and M30 threaded body for E2E-X23B230 2M.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 23MM PNP M30 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
The supply range permits a new machine design-in
10V ~ 30V is the listed supply range; a control rail outside it rules out this sensor before mounting begins. Omron E2E-X23B230 2M is Active, with aligned lifecycle signals, making new design-in reasonable rather than a sustaining-only choice. EU RoHS compliance is listed, but it says nothing about whether the output can drive the intended input.
Cable leads put termination work on the line
Will the line need a connector termination? This part is specified with cable leads and box packaging. Put termination in the harness instructions before releasing machine wiring; the box doesn't remove that step.
An NPN input rules out this PNP-NC sensor
It's wrong for an NPN input or a normally open sensing channel. It belongs on a PNP-NC, 3-wire input where an inductive sensor can be threaded into an M30 mount. The listed 23mm sensing distance sets the starting geometry, not a promise of detection at that separation for every target, so check target geometry before fixing the mount; a wrong assumption risks intermittent misses.
The -25°C ~ 70°C operating temperature range rules out placements beyond those conditions. IP67 and IP69K are listed ingress ratings, not permission to exceed that temperature range. The shielded, nickel-plated brass body helps define the mounting choice, but it does not change the required input type.
The 200Hz ceiling leaves switching details open
200Hz is the listed response-frequency ceiling, not a guarantee of switching behavior at every target speed. Response-time characteristics are absent, so the timing decision remains open. The output load-current limit is also absent; PNP-NC, 3-wire alone cannot close the controller-interface check. Get the cable wiring diagram and M30 mechanical drawing before releasing the harness and bracket.
View the Win-Source product page for E2E-X23B230 2M.
Key Takeaways for Engineers & Buyers
- Keep the control rail within the listed 10V ~ 30V supply range.
- Check target geometry against the listed 23mm sensing distance.
- Put cable-lead termination in the harness instructions before fixing the M30 mount.