10V–30V supply, 23mm sensing distance, M30 threaded body and PNP-NC output
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 23MM PNP M30 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
Is this M30 sensor a new-design part?
Can this sensor go on a new machine BOM? Yes. Both lifecycle and product-status fields say Active, with no stated conflict; EU RoHS compliance is listed too. That clears a selection hurdle, but the PNP-NC output still has to suit the machine input and the threaded body has to fit its bracket.
PNP-NC rules out the wrong controller input
A controller expecting an NPN or normally open signal is the wrong destination. The specified PNP-NC, 3-Wire output needs an input designed for that logic. The listed supply range has a 10V lower limit and a 30V ceiling, not a target rail. Those limits establish supply compatibility, but they say nothing about how much load the output can drive.
The 23mm distance still needs a real target
And getting the logic right still leaves the target. The listed 23mm sensing distance is a starting point for placement, not a guarantee of detection at every position with the machine’s actual target. The shielded, M30 threaded nickel-plated brass body points to a fixed mount, while its cable leads need a routed exit rather than a connector at the sensor. IP67 and IP69K are listed ingress ratings; neither settles target geometry.
The M30 mount fixes the buying decision
The M30 thread constrains the bracket and harness: buy the cable-lead version only when both are planned around that body. Box packaging does not change the termination. Commit the mounting arrangement before releasing this part for a running line.
The 200Hz limit does not finish the machine check
The limits won’t close qualification. The listed 200Hz response frequency is a ceiling, not proof that a moving target remains detectable at the chosen machine speed. The operating temperature range of -25°C to 70°C excludes installations beyond those bounds, and it does not establish the permitted output load.
For E2E-X23B230 5M, the missing output load-current rating blocks electrical sign-off of the controller input and any attached load. The wiring diagram must establish conductor assignments; the mounting drawing must locate the M30 body. Sensing-distance behavior against the actual target must close the detection geometry. Those details are absent here.
View the Win-Source product page for E2E-X23B230 5M.
Key Takeaways for Engineers & Buyers
- Match the PNP-NC, 3-Wire output to the controller input.
- Reserve an M30 threaded mounting position for the shielded body.
- Get the output load-current rating before approving the input circuit.