Omron E2E-X23B230-R 5M: Active for New Designs

E2E-X23B230-R 5M Omron product image

23mm sensing distance, M30 thread and 10V ~ 30V supply limits set the first fit checks.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 23MM PNP M30 NC
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

Is 23mm enough for this shielded M30 sensor?

23mm is the listed sensing distance, a starting point for testing the actual metal target rather than proof of detection. This shielded inductive sensor is Active across its lifecycle signals, making new design-in reasonable; it is also marked compliant with EU RoHS.

The M30 threaded body and PNP-NC, 3-wire output are firmer fit gates. A controller expecting a different output state, or a mount that cannot take the thread, rules out Omron E2E-X23B230-R 5M regardless of sensing distance.

The 30V supply limit is not a rail target

30V is the listed supply ceiling, not a working setpoint. The lower listed limit is 10V; outside those limits, the sensor is ruled out. The 200Hz response-frequency figure bounds event rate but doesn't specify switching delay.

Will the M30 cable-lead version fit the running line?

Will the line accept cable leads rather than a connector? This M30 version lists cable leads as its termination, while Box describes packaging; neither implies a plug. Keep E2E-X23B230-R 5M and its cable-lead termination together on the BOM so a running build does not assume a connectorized part.

Ingress ratings help; target and wiring details are still absent

The actual target remains the weak point: no target-material sensing curve is listed, so the stated distance cannot settle a metal-changeover test. Environmental fit has firmer boundaries. The -25°C ~ 70°C operating temperature limits set the ambient range, while IP67 and IP69K are listed ingress ratings for choosing an installation, not proof that an installed cable splice is sealed.

An output load-current limit is absent, so the PNP-NC input load can't be cleared. There is no cable-lead wiring diagram to assign the leads confidently. A mounting drawing is absent too; the M30 thread alone does not close mechanical fit.

View the Win-Source product page for E2E-X23B230-R 5M.

Key Takeaways for Engineers & Buyers

  • Test the actual metal target against the listed 23mm sensing distance.
  • Keep the supply within the listed 10V ~ 30V limits.
  • Match the PNP-NC, 3-wire cable leads to the control input.