Omron E2E-X23C130 5M: Active for new inductive designs

E2E-X23C130 5M Omron product image

23mm sensing, 200Hz response and M30 threading; the NPN-NO cable output needs a matching input.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 23MM NPN M30 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

An NPN input is the starting condition

A PNP input is the wrong destination for this NPN-NO, 3-wire inductive sensor. For a machine input built to accept NPN-NO switching, E2E-X23C130 5M is a reasonable new design-in: its lifecycle signals agree on Active, and EU RoHS compliance is listed. The shielded, threaded M30 body belongs at a machine bracket rather than on a circuit board, so that mounting choice needs to be made before the bracket is released.

The 23mm reach is a limit, not a target position

23mm is the listed sensing-distance ceiling, not a promise that every target will switch at that gap. Target and mounting conditions still matter. The listed 200Hz response figure bounds the event-rate decision but doesn't establish timing margin for a moving target.

Cable leads make assembly instructions matter

Cable leads need a build step. Box packaging and cable leads call for defined routing and termination, not an assumed plug-in connection. Put that step in the build instructions before releasing E2E-X23C130 5M to existing production; different cable handling at each station makes the installed sensor position harder to repeat.

Supply limits leave the wiring and mounting details open

10V ~ 30V is the listed supply range. A controller rail outside it rules the sensor out. The -25°C ~ 70°C operating-temperature range screens the installation environment, but neither range settles the connection or mounting details.

The listing omits an output load limit, a wiring diagram, and a mounting drawing. The load limit must establish whether the chosen input can be driven without overstressing the output; the diagram must settle the cable connections, while the drawing must settle bracket clearance around the threaded body. IP67 and IP69K are listed, but they don't describe how to install the cable exit for washdown.

View the Win-Source product page for E2E-X23C130 5M.

Key Takeaways for Engineers & Buyers

  • Check target spacing against the listed 23mm sensing-distance ceiling.
  • Compare the 200Hz response figure with the machine's event rate.
  • Reserve an M30 mounting position before releasing the bracket.