23mm sensing distance, 200Hz response frequency, M30 body and 10V–30V supply limits.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 23MM NPN M30 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
Can this M30 sensor go into a new build?
Can I specify this sensor for a new build? Yes. Lifecycle and product status both say Active, with no stated conflict; EU RoHS compliance is listed. For existing production, keep the cable-lead termination on the build record to prevent a harness mismatch at assembly.
The 23mm reach must work at the machine
The 23mm sensing distance limits where the target can sit. It is a reach to assess, not a guaranteed switching point for every target and mounting arrangement. This shielded M30 inductive sensor belongs at a fixed machine position where that reach can be checked against the actual target, not at a station whose target sits beyond it.
The 200Hz response frequency is a ceiling, not a promise about individual switching events. Compare it with the required event rate for a fast-moving target. The machine’s supply must also stay within the 10V–30V limits; 30V is the upper limit, not a working setpoint.
70°C is the upper operating-temperature limit
70°C is the top of the listed operating-temperature range, which starts at -25°C. A mounting point outside that range is out of bounds even if the housing suits the washdown area. IP67 and IP69K address ingress protection, not temperature headroom. The threaded M30, nickel-plated brass body and cable leads make placement and routing part of the choice. The NPN-NO, 3-wire output must match the machine input.
What remains open before the M30 mount is fixed?
And that still leaves the switching and installation details open. No target-material derating information is listed for E2E-X23C1L30 5M, so 23mm alone cannot settle the trip position for the machine’s target. It doesn’t list an output load-current limit either; without that ceiling, the NPN-NO input connection cannot be signed off.
The wiring diagram and dimensioned drawing are also absent. Get both before fixing the cable connection or cutting the M30 mount, because a correct sensing distance will not save a build whose leads are wired to the wrong input or whose sensor cannot be positioned where the target passes.
View the Win-Source product page for E2E-X23C1L30 5M.
Key Takeaways for Engineers & Buyers
- Check the 23mm sensing distance against the actual target and mounting position.
- Compare the required event rate with the 200Hz response-frequency ceiling.
- Match the M30 cable-lead assembly to the NPN-NO, 3-wire input.