23mm sensing ceiling, 10V to 30V supply bounds and an M30 threaded body.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 23MM NPN M30 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new inductive-sensor build
So this belongs on a new-build shortlist, not a released drawing. Omron lists both lifecycle and product status as Active, supporting design-in and continued use on a running line. It is also listed as EU RoHS compliant. Reach and output still have to match the machine.
Can the line accept boxed, cable-lead sensors?
Does it come with a connector? E2E-X23C230 2M is listed with Box packaging and cable-lead termination. A line built around connector-ended sensors needs a different termination step; put it in the work instructions before changing a running line. Active status does not erase assembly rework.
The 23mm reach is a ceiling, not a target position
23mm is the listed sensing-distance ceiling. That doesn't establish reliable detection at that gap for every target; the actual target and mounting position decide whether the sensor has enough reach. The 200Hz response-frequency ceiling limits how fast a target pattern can be counted, but it is not a switching-time specification.
The 10V to 30V supply range rules out a rail beyond those bounds, while a rail inside them still says nothing about whether the controller accepts the output. The -25°C to 70°C operating-temperature range sets the ambient boundary for placement. Mounting above 70°C risks missed detections even with the controller input wired correctly.
NPN-NC wiring and the M30 body set the installation fit
The output-state constraint comes first. A machine expecting something other than a 3-wire NPN-NC output can't treat this as a wiring-only change. The shielded, M30 threaded cylinder needs a matching mount, with its cable leads routed to the input. IP67 and IP69K describe the sensor's listed ingress protection, not protection for the completed cable connection.
The remaining gaps are electrical and mechanical
Three gaps remain. Target-dependent sensing curves, a response-time specification and a cable wiring diagram are absent; those details are needed to settle reach, timing and termination before release.
View the Win-Source product page for E2E-X23C230 2M.
Key Takeaways for Engineers & Buyers
- Check target reach against the 23mm sensing-distance ceiling.
- Match the controller input to the 3-wire NPN-NC output.
- Check the mounting hole against the M30 threaded body.