Omron E2E-X23C230-M1: Active for New Industrial Designs

E2E-X23C230-M1 Omron product image

23mm sensing distance, M30 body, 10V ~ 30V supply limits, and -25°C ~ 70°C operating temperature

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 23MM NPN M30 NC
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

Active status makes this M30 sensor a new-design candidate

Even so, Active status settles only the lifecycle question. I'd consider E2E-X23C230-M1 for a new industrial sensing position: all listed lifecycle signals agree on Active, with no stated conflict. The listed 23mm sensing distance gives the fixture designer a starting point, but it does not establish detection distance for every target and mounting arrangement; test the actual target before fixing the bracket.

The shielded inductive sensor belongs in a threaded M30 mount where the controller accepts an NPN-NC, 3-wire output. An input expecting different output behavior rules it out without an interface change. Plan for the connector termination rather than treating it as a loose-wire installation. IP67 and IP69K are listed, but neither rating replaces a check of the installed connector and mounting arrangement.

The M30 outline still leaves the fixture unfinished

The missing mounting drawing leaves the fixture unfinished, though the M30 threaded-cylinder description identifies the mount to investigate. The connector pinout and target-dependent sensing data are also absent; the short description cannot settle fixture and wiring decisions without them.

Supply and response limits set different boundaries

The supply range sets the control-rail boundary: 30V is a listed ceiling, not a preferred setpoint, while a rail below 10V falls outside the stated 10V ~ 30V range. The 200Hz response-frequency figure is also a ceiling, not proof that every short passing feature will register. If missed detections stop the machine, test the intended target motion rather than treating that figure as a pulse guarantee. The -25°C ~ 70°C operating-temperature range bounds the stated envelope; it does not settle the temperature at the installed sensor.

Keep the connector fixed on a running line

Keep the connector fixed. For existing production using E2E-X23C230-M1, the connector termination is the purchasing constraint that can turn a sensor change into a wiring change. Record the mating connector on the line BOM before releasing builds. The part is listed as EU RoHS compliant.

View the Win-Source product page for E2E-X23C230-M1.

Key Takeaways for Engineers & Buyers

  • Test the intended target at the listed 23mm sensing distance.
  • Check the control input against the NPN-NC, 3-wire output.
  • Identify the mating connector before releasing the line BOM.