Omron E2E-X23C230-R 2M: Active for new designs

E2E-X23C230-R 2M Omron product image

23mm sensing distance, M30 body and 10V to 30V supply range set the fit.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 23MM NPN M30 NC
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

Active status supports an M30 design-in, with a target check

The 23mm sensing distance isn't a detection guarantee for every target. Both lifecycle and product status read Active, supporting new design-in where the shielded M30 threaded body fits the bracket and the controller expects a 3-wire NPN-NC output.

Set that normally closed input logic deliberately: a broken cable or lost supply must not be mistaken for the intended machine state. IP67 and IP69K are listed for the sensor, not as proof that the installed cable termination meets either rating. It is marked compliant with EU RoHS.

The supply ceiling and response frequency set different limits

That fit still depends on the listed 10V to 30V supply range: 30V is the ceiling, not a target rail, and 10V is the lower bound to check at the sensor. The -25°C to 70°C operating-temperature range sets the stated ambient bounds; 70°C is not permission to ignore a hotter mounting point.

The listed 200Hz response frequency can rule out a faster detection requirement, but it does not specify the switching delay needed to set controller input filtering.

M30 threads and cable leads must match the order

M30 threading calls for a bracket; this is not a drop-in choice for a connectorized socket. E2E-X23C230-R 2M is listed with cable leads and box packaging. Put the cable-lead termination and M30 body on the order so the delivered configuration matches the bracket and wiring plan. Shielded construction matters near surrounding metal, but it does not settle mounting clearance.

The 23mm reach still needs target and mounting detail

Target margin remains the constraint. The 23mm reach can't settle it alone: the datasheet still has to supply target-material correction, a mounting drawing, the output-load limit and a wiring diagram before the bracket and controller input can be released.

View the Win-Source product page for E2E-X23C230-R 2M.

Key Takeaways for Engineers & Buyers

  • Check the 10V to 30V supply range at the sensor terminals.
  • Test 23mm detection against the actual target and mounting position.
  • Map the 3-wire NPN-NC output to the controller's fault response.