Omron E2E-X2B1T12 5M: Active for New Machine Designs

E2E-X2B1T12 5M Omron product image

2 mm sensing distance, 10 V to 30 V supply, threaded M12 body, and cable leads.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M12
Core functionSENSOR INDUCT 2MM PNP M12 NO
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 30V

The 2 mm reach makes target position the design-in gate

2 mm is the listed inductive sensing distance. E2E-X2B1T12 5M fits a new design only where the target can enter that range; the number alone does not settle mounting tolerance or target-material effects. Its lifecycle fields agree on Active, and EU RoHS compliance is stated.

Cable leads change the sustaining build

Does the assembly expect a connector? This sensor has cable leads on a threaded M12 cylindrical body. Before using it on an existing production line, put that termination and mounting arrangement on the build drawing; a station set up for a plug-in sensor could stall at installation even if the sensing behavior fits. Box describes the packaging, not the electrical interface.

The supply range cannot fix a mismatched control input

10 V to 30 V is the listed supply range. It provides a rail-compatibility check, not permission to exceed its upper end. The −40°C to 85°C operating temperature range bounds the stated environmental fit but does not settle the temperature at the installed cable exit. Check both before placing the sensor near a hot process.

The shielded inductive sensor has a PNP-NO, 3-wire output and needs a compatible control input, not a station expecting a different output arrangement. Its 1.5 kHz response frequency matters for a moving target, but that figure alone does not establish detection at the machine’s target speed.

The PNP-NO cable still needs wiring details

The wiring is not settled. Without a wiring diagram, PNP-NO, 3-wire does not identify which cable lead lands on each control terminal. The dimensional drawing is absent too: M12 names the thread, not the clearance needed at the cable exit. Get those drawings and the absent output load-current limit from the datasheet before releasing the machine wiring.

View the Win-Source product page for E2E-X2B1T12 5M.

Key Takeaways for Engineers & Buyers

  • Check target travel against the listed 2 mm sensing distance.
  • Match the control rail to the 10 V to 30 V supply range.
  • Specify cable-lead termination for the threaded M12 installation.