Omron E2E-X2B1T8-M1: Active for new inductive sensor designs

E2E-X2B1T8-M1 Omron product image

2mm sensing, 10V ~ 30V supply limits, M8 body and -40°C ~ 85°C operating temperature.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 2MM PNP M8 NO
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 30V

A 2mm target gap makes mounting the first decision

2mm is the listed sensing distance, so E2E-X2B1T8-M1 is a new-design candidate where the metal target gap can be controlled, not where bracket movement may consume that distance. The shielded, threaded M8 body gives the mount a starting point, but the 2mm figure does not settle target-material effects or sensing-face position. Its PNP-NO, 3-Wire output needs a compatible controller input; a controller expecting the opposite output behavior rules it out.

Can this sensor stay on a running line?

Can it stay on a running line? Lifecycle Status and Product Status both say Active, with no stated conflict, so the lifecycle supports existing production and new design-in. The Box package doesn't define a mating connector; lock down that interface before a line build rather than treating “Connector” as a complete wiring specification. EU RoHS compliance is stated.

The 10V ~ 30V supply limits bound the rail choice. 30V is a ceiling, not a working setpoint, and those limits do not establish the permissible output load. The -40°C ~ 85°C operating-temperature range covers the specified ambient endpoints, not whatever temperature develops inside a particular installation. IP67 and IP69K are listed ingress ratings, but neither settles the seal at the installed connector.

Does 1.5kHz settle detection of a passing target?

1.5kHz is the listed response frequency, not a promise that every passing target produces a pulse the controller can capture. Switching-time detail is absent; target geometry and controller sampling still decide whether that frequency is useful.

The M8 body still needs a drawing and pinout

The wiring details are missing. E2E-X2B1T8-M1 has no stated output-load limit or connector pinout here, so the PNP-NO, 3-Wire description cannot close the controller-input or cable-mating checks. A dimensional drawing is also needed to place the sensing face relative to the target; an M8 thread designation alone cannot do that job.

View the Win-Source product page for E2E-X2B1T8-M1.

Key Takeaways for Engineers & Buyers

  • Check the target gap against the listed 2mm sensing distance.
  • Match the controller input to the PNP-NO, 3-Wire output.
  • Specify connector sealing for IP67 and IP69K installations.