Omron E2E-X2B1TL8-M3: Active for new machine designs

E2E-X2B1TL8-M3 Omron product image

2mm sensing, 10V–30V supply limits, M8 threaded body and -25°C to 70°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 2MM PNP M8 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 30V

Active status supports a new machine build

New design-in is supported. Omron’s E2E-X2B1TL8-M3 has aligned Active lifecycle and product-status entries, so its status does not confine it to sustaining designs. EU RoHS is marked compliant, with no revision stated.

Electrical fit is a separate question. This shielded inductive sensor has a PNP-NO, 3-wire output and belongs on a machine input wired for that behavior, not one expecting a different polarity or a normally closed signal.

A 2mm target gap drives the sensing decision

But the listed 2mm sensing distance leaves little room for casual target placement; it does not establish detection distance for every target material or mounting arrangement. The listed 10V and 30V supply boundaries screen the controller rail. Treat 30V as a ceiling, not a working setpoint.

The listed 1.5kHz response frequency helps screen a moving-target application, but it gives no switching delay at the machine input. If target speed makes that distinction matter, frequency alone cannot settle the timing decision.

Will the M8 sensor fit the installed harness?

Will the existing harness actually mate? The M8 threaded cylindrical body defines the mounting interface, while “Connector” identifies the termination style. It doesn’t identify a mating cable. E2E-X2B1TL8-M3 can fit a threaded sensor position, but the connector interface must be settled before a running line commits to a harness.

The stainless-steel body and IP67/IP69K ingress ratings warrant consideration around washdown equipment. Those ratings do not establish the protection of an unspecified mated connection. The -25°C to 70°C operating-temperature range screens the installation environment; outside that range, no operating claim is given here. Match the mounting and cable before releasing the machine build, since either mismatch can stop assembly despite the Active status.

The 2mm distance still needs a mounting drawing

A 2mm sensing distance constrains target geometry. A mechanical drawing and sensing-distance detail for the intended target would settle placement. The connector pinout and output-current rating are also absent, leaving the mount and input wiring unreleased.

View the Win-Source product page for E2E-X2B1TL8-M3.

Key Takeaways for Engineers & Buyers

  • Check the 2mm sensing distance against target placement.
  • Keep the supply within the listed 10V–30V boundaries.
  • Resolve the M8 connector pinout before harness release.