2mm sensing distance, M12 threaded body, 10V–30V supply limits, -40°C to 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR INDUCT 2MM NPN M12 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 30V |
The 2mm reach rules out distant targets
Long-range sensing is the wrong job. Omron E2E-X2C112 2M is Active for new designs with a shielded, threaded M12 installation where the listed 2mm sensing distance fits the target clearance. Both lifecycle fields agree; the part is EU RoHS compliant.
Supply and response limits narrow the control setup
The rail and switching budget constrain the control setup. The listed 10V–30V supply range bounds the rail choice: 30V is a ceiling, not a setpoint, and a rail outside that range is not covered by the listing. Compare the 1.5kHz response-frequency figure with the event rate; that limit does not establish switching behavior for a particular target or installation.
The -40°C to 85°C operating range sets the stated temperature envelope for E2E-X2C112 2M. It does not settle performance at a tight sensing gap across that range.
Cable leads, not the M12 thread, decide the harness
Does the assembly use cable leads? E2E-X2C112 2M lists cable-lead termination; M12 describes the threaded body. Put the termination on the BOM and harness drawing before release. An M12 thread isn't evidence of a plug connection or a matching electrical interface.
The 2mm distance still leaves mounting questions
2mm is the listed sensing distance, not a completed clearance check. Target-material response and a mounting drawing are absent, so the datasheet still has to establish the installed gap and threaded seating. Cable conductor assignments are absent too; guessing the wiring for this NPN-NO, 3-wire output risks a dead input. No output-current rating is listed, leaving the input interface check open.
View the Win-Source product page for E2E-X2C112 2M.
Key Takeaways for Engineers & Buyers
- Budget target clearance against the listed 2mm sensing distance.
- Match the 10V–30V supply limits to the control rail.
- Put cable-lead termination on the harness drawing; M12 describes the body.