Omron E2E-X2C18-M3: Active for new industrial designs

E2E-X2C18-M3 Omron product image

2mm sensing distance, 10V to 30V supply limits, M8 body, -25°C to 70°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 2MM NPN M8 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 30V

An NPN input and an M8 mount make the fit

A PNP-only input is the wrong home for E2E-X2C18-M3. The NPN-NO, 3-wire inductive sensor needs a compatible input and room for its threaded M8 stainless-steel body. Its lifecycle fields agree on Active, with no conflicting signal, so it suits new design-in as well as existing production where the fit works. EU RoHS compliance is listed.

The 2mm gap decides more than the M8 thread

The gap is tight. The listed 2mm sensing distance puts target placement ahead of output selection, since a bracket that carries the target beyond that distance cannot be rescued by changing the controller input. Check the intended target and installed gap before fixing the mount.

The 10V to 30V supply range sets the rail boundaries, not a preferred working setpoint. A rail outside that range falls outside the listed supply conditions. The -25°C to 70°C operating range also sets a ceiling: a hotter enclosure rules out a straightforward fit. The listed 1.5kHz response frequency helps screen the motion rate, but it doesn't establish that the controller will register every brief target passage.

Can the line kit a Box-packaged sensor?

Will Box packaging work with the line's kitting setup? Box is the listed package designation. Put it on the purchasing line and align the kitting instructions before releasing the assembly order; a line set up for a different presentation can stall even when the M8 sensor fits.

The connector details still gate release

Even then, the hookup remains unresolved. The connector pinout, mating-connector drawing, output load-current limit, and switching-time specification are absent. Without them, NPN-NO, 3-wire and 1.5kHz alone cannot settle the cable assembly or whether the controller will register brief target passages.

View the Win-Source product page for E2E-X2C18-M3.

Key Takeaways for Engineers & Buyers

  • Set the installed target gap against the listed 2mm sensing distance.
  • Match the controller input to the NPN-NO, 3-wire output.
  • Specify Box packaging for line kitting.