2mm sensing distance, 10V to 30V supply, M8 threaded body, and -25°C to 70°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 2MM NPN M8 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 30V |
The supply range clears one hurdle, not the installation
10V to 30V is the listed supply range. A rail outside those bounds rules out E2E-X2C1L8 5M before target geometry matters. For a new design-in, the controller must accept its NPN-NO, 3-wire output. Lifecycle signals agree on Active, and the sensor is listed as EU RoHS compliant.
Cable leads and box packaging leave termination to the assembly instructions; don't expect a connector with the sensor.
The 2mm reach puts the target first
2mm is the listed sensing distance, not a promise that every metal target switches at that gap. Check fixture travel before choosing the mounting point: an M8 threaded body cannot recover detection once the target moves beyond the listed reach.
A 2mm reach leaves little room for misplaced targets
Target placement is the tight constraint. The 2mm reach constrains fixture travel more than the M8 thread simplifies mounting. A nonmetal target defeats this shielded inductive sensor's sensing method; a controller input expecting a different output type rules out its NPN-NO, 3-wire signal.
The listed 1.5kHz response frequency is a ceiling for event-rate checks; it doesn't prove that every target will be detected at that rate in the machine. The -25°C to 70°C operating range sets ambient bounds, so a mounting location outside them is unsuitable. IP67 and IP69K are listed ingress ratings. The body is stainless steel, but neither those ratings nor the body material resolves how the cable exit will hold up to handling at the chosen mounting point.
Wiring and mounting still need drawings
Hold release. The pinout and output load-current limit are absent, leaving the 3-wire connection and electrical load unresolved. The mounting drawing and target-dependent sensing curve are absent too; without them, the installed M8 fit and reliable switching within the listed 2mm distance remain unresolved.
View the Win-Source product page for E2E-X2C1L8 5M.
Key Takeaways for Engineers & Buyers
- Check fixture travel against the listed 2mm sensing distance.
- Match the machine rail to the 10V to 30V supply range.
- Write cable-lead termination into the assembly instructions.