Omron E2E-X2C1L8-M3: Active for New Inductive Designs

E2E-X2C1L8-M3 Omron product image

2mm sensing, 10V to 30V supply, M8 thread: check target spacing and input compatibility.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 2MM NPN M8 NO
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 30V

A 2mm sensor is no answer to a distant target

Long-reach detection is the wrong job. E2E-X2C1L8-M3 is a shielded inductive sensor with a stated 2mm sensing distance, so mounting must bring the metal target close to its face, though that rating does not establish detection distance for every target material. Its NPN-NO, 3-Wire output needs an input that accepts a sinking signal.

For close-range sensing, new design-in is reasonable: the lifecycle signals agree on Active, and the part is listed as EU RoHS compliant.

The supply ceiling is not a rail target

30V is the upper supply ceiling, not a working setpoint. The range starts at 10V; a control rail outside those bounds rules out this sensor before mounting details matter. The specified operating-temperature range runs from -40°C to 85°C. A hotter location falls outside it, regardless of the stainless-steel body.

The 1.5kHz response-frequency ceiling helps screen the event rate, but it does not establish response behavior under every target and installation condition.

The M8 mount makes the connector a purchasing decision

The threaded mount and connector narrow the installation choices. E2E-X2C1L8-M3 belongs in an M8 threaded sensor mount, with a mating connector specified on the BOM. It isn't a cable-tail termination; treating it as one would stall assembly.

The stated IP67 and IP69K protection supports considering it where ingress exposure matters. Neither rating settles how the installed connector and mounting arrangement perform.

What still blocks the input and mount?

The input circuit remains unsettled. The connector pinout, output load-current limit, and dimensional drawing are not specified here; get them from the datasheet before locking the control input and bracket.

View the Win-Source product page for E2E-X2C1L8-M3.

Key Takeaways for Engineers & Buyers

  • Keep the metal target within the stated 2mm sensing distance.
  • Match the 10V to 30V supply range to the control rail.
  • Specify a mating connector for the M8 sensor before BOM release.