2mm sensing distance, 10V ~ 30V supply bounds, and a threaded M12 body.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR INDUCT 2MM NPN M12 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 30V |
The 2mm gap makes mounting the first decision
2mm is the listed sensing distance. Bracket tolerance cannot consume that gap if the metal target is to stay close to the sensing face. E2E-X2C212-R 5M suits a new design where its shielded, threaded M12 body can be mounted repeatably. It's a poor choice if the target cannot stay close.
Supply and temperature bounds narrow the fit, not the wiring
A 1.5kHz response-frequency listing doesn't prove reliable detection at every installed gap and target speed. It gives the motion design a screening figure, not a completed timing check. The 10V ~ 30V supply bounds rule out a rail outside that range; 30V is a ceiling, not a preferred setpoint. The -40°C ~ 85°C operating temperature range screens the installation ambient but does not establish the margin left in a particular mounting arrangement.
IP67 and IP69K are listed ingress ratings, useful near washdown or spray, but neither settles how the cable exit must be installed to retain that protection. The receiving circuit must also accept the listed NPN-NC, 3-wire output before the line is wired.
Will the cable-lead version match the running line?
Will the installed harness accept cable leads rather than a connector? That is the buying question for E2E-X2C212-R 5M. The sensor is box-packaged, and the wrong termination changes assembly work even when the M12 mounting fits. Keep the full part number on the BOM and check the termination before releasing a repeat build. Both lifecycle fields say Active, and EU RoHS compliance is listed.
The bracket and input still need missing details
The listing stops short. Obtain the mechanical drawing and wiring diagram before fixing the bracket or input connections. The output load-current limit and sensing-distance curves are also absent; both matter to the installed target and receiving input.
View the Win-Source product page for E2E-X2C212-R 5M.
Key Takeaways for Engineers & Buyers
- Set the target gap against the listed 2mm sensing distance.
- Match the input to the NPN-NC, 3-wire output.
- Check the bracket against the threaded M12 body and cable-lead exit.