2mm sensing-distance ceiling, M8 thread, 10V ~ 30V supply; NPN-NC output fixes the control-input choice.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 2MM NPN M8 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 30V |
The 2mm gap decides the design-in
2mm is the sensing-distance ceiling, not a mounting gap to assume across every target. Exceed it and detection can fail, regardless of the wiring. With the part listed Active and no conflicting lifecycle signal, there's no stated lifecycle reason to restrict E2E-X2C28-R 2M to sustaining designs, provided target travel stays within that ceiling. The short reach is the first decision.
NPN-NC rules out a sourcing-input assumption
A controller expecting a sourcing sensor output is the wrong home for this NPN-NC, 3-Wire device. The listed 1.5kHz response frequency is a ceiling, not proof that every passing target will be detected at that rate; check the intended motion against the sensing setup. The shielded, threaded M8 body fits a mounted industrial sensing position. IP67 and IP69K are listed ingress-protection ratings, but they don't remove the need to install the cable properly.
View the Win-Source product page for E2E-X2C28-R 2M.
The supply and temperature bounds still matter
10V ~ 30V defines the listed supply bounds. Design around that rail; input behavior outside the range isn't stated. The specified operating-temperature range is -25°C ~ 70°C, so a location beyond either end falls outside it. Neither range rescues a target placed beyond the 2mm sensing-distance ceiling.
Cable leads make repeatable assembly the buying constraint
That leaves the harder part of line assembly: keeping the cable-lead installation consistent. Box packaging and cable leads make this a routed, terminated component rather than a board-placement item. Put the cable path and M8 mounting location on the work instruction, then define the controller-input state expected during the station check.
An NC output interpreted as NO can produce a control fault even when the sensor body fits. The LED gives a local indication, but the station check still needs to observe the controller input. The part is listed compliant with EU RoHS.
The missing wiring details block fixture release
The weak point is the missing interface detail, despite the stated NPN-NC, 3-Wire output. The cable-lead pinout, output load-current limit, and mechanical drawing are still needed before wiring and fixture release.
View the Win-Source product page for E2E-X2C28-R 2M.
Key Takeaways for Engineers & Buyers
- Set target travel against the 2mm sensing-distance ceiling.
- Match the controller input to NPN-NC, 3-Wire signaling.
- Fix M8 mounting and cable-lead routing in the build instruction.