2 mm sensing distance, M12 threaded body, 10V ~ 30V supply limits and -40°C ~ 85°C operating temperature.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR INDUCT 2MM NPN M12 NO/NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 30V |
A 2 mm target gap makes the first decision
2 mm is the listed sensing distance. For E2E-X2C3L12 2M, it is a starting point for target placement, not a promise that an arbitrary target will switch reliably at that gap. The shielded, threaded M12 body suits a machine mount with little room between sensor and target; it is the wrong choice if that geometry cannot be held.
The lifecycle status is Active, with no conflicting signal listed. New design-in is reasonable where that geometry fits. EU RoHS is marked compliant.
Can the M12 mount and cable leads stay on the line?
Will the threaded M12 body and cable leads fit this machine? The threaded cylinder and cable leads must both work in the layout, so keep the mount and cable route in the build instructions rather than treating E2E-X2C3L12 2M as a connectorized sensor. The Box package does not change the termination. Its NPN-NC/NO, 3-wire output must match the controller input; an identical mounting position will not rescue a mismatched input circuit.
IP67 and IP69K are listed ingress-protection ratings relevant to a wet machine location. They don't settle how the installed cable exit is protected. Check that detail each time the sensor is fitted.
The output name is not a wiring drawing
No wire-color assignment or mounting drawing is listed. The NPN-NC/NO, 3-wire designation still identifies the output arrangement. Sensing hysteresis and the output load-current limit are absent too; get those details before releasing the wiring and target layout.
The supply window limits the rail; response limits the event rate
The rail must stay within the listed 10V ~ 30V supply limits for E2E-X2C3L12 2M; those limits do not specify a preferred setpoint. The -40°C ~ 85°C operating temperature range bounds where the sensor can be installed, but it says nothing about temperature at an unmeasured mounting location.
The listed 1.5kHz response frequency sets a ceiling for the event-rate case you can make from this specification; it does not establish switching behavior for every target passing the 2 mm sensing zone. Fast motion needs more than that number.
View the Win-Source product page for E2E-X2C3L12 2M.
Key Takeaways for Engineers & Buyers
- Check the target gap against the listed 2 mm sensing distance.
- Match the controller input to the NPN-NC/NO, 3-wire output.
- Get the cable drawing before fixing the M12 mounting route.