2mm sensing distance, 10V to 40V supply limits, threaded M12 body; sustaining designs only.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 40V |
A 2mm reach leaves little room for mounting error
2mm is the listed sensing distance. That's a close-target job, not a way around a bracket that leaves a wider gap. The shielded, threaded M12 body needs a machine mount with that thread and a target within reach.
The lifecycle parameter says EOL, and both status fields say Discontinued. The labels differ; the decision doesn't. No new design-in. Keep E2E-X2E1-5M on sustaining designs.
The supply limits can veto an otherwise good mechanical fit
Even then, a close mechanical fit does not settle the input circuit. The listed 10V to 40V supply range bounds the rail choice: 40V is a ceiling, not a working target, and a rail outside the range rules this sensor out. The NPN-NO, 3-Wire output needs an input wired for that signaling; thread size alone cannot settle the choice. The 1.5kHz response-frequency limit can screen a fast application, but it is not a switching waveform.
Bulk cable leads make the installed wiring the buying constraint
Keep it in sustaining designs. The -40°C to 85°C operating-temperature range bounds the installed environment. Its 85°C upper limit is no reason to ignore heat at the sensor mount, while the listed IP67 ingress protection says nothing about a cable joint whose construction is unspecified.
With bulk packaging and cable leads rather than a listed connector, E2E-X2E1-5M needs to match the existing wiring and threaded mounting before it goes into a running line, even when the sensing distance fits. A mismatch can stop installation. Secure parts for existing production and plan migration away from this discontinued sensor. EU RoHS compliance does not change that lifecycle decision.
The M12 thread is known; the mounting drawing is not
A dimensioned drawing is absent, but the threaded M12 housing is identified. The mounting envelope remains open. The cable-lead wiring diagram and switching hysteresis are also absent, leaving the electrical connection and target transition unresolved.
View the Win-Source product page for E2E-X2E1-5M.
Key Takeaways for Engineers & Buyers
- Check the installed target gap against the listed 2mm sensing distance.
- Keep the supply within the listed 10V to 40V limits.
- Reserve E2E-X2E1-5M for existing production; plan migration.