Omron E2E-X2F1-5M: Discontinued, for Sustaining Builds

E2E-X2F1-5M Omron product image

2 mm sensing distance, 10V ~ 40V supply and M12 threaded body; discontinued for new designs.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M12
Core functionSENSOR PROX INDUCTIVE 2MM CYL 5M
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 40V

A 2 mm target path leaves little room to move

2 mm is the listed sensing distance. A target that cannot pass close to the face rules this sensor out. The shielded M12 threaded body belongs at a close machine-mounted sensing point, not across a wide gap.

Discontinued means sustaining builds only

Don't design it in. One lifecycle field says EOL; the lifecycle and product status fields say Discontinued. Neither supports a new design. E2E-X2F1-5M belongs on a sustained existing production line while migration is planned. It is listed as EU RoHS compliant.

The supply range does not settle moving-target detection

40V is the upper listed supply limit; 10V is the lower one. That range screens the rail but does not establish tolerance for rail transients, while the -40°C ~ 85°C operating-temperature range sets ambient bounds without proving detection of the installed target at either extreme.

The listed 1.5kHz response frequency helps screen a moving-target application, but without response test conditions it cannot establish the shortest detectable pass. The PNP-NO, 3-wire output must match the existing input or the machine will not read the sensor as intended. IP67 addresses ingress protection, not sensing distance.

Will bulk packaging work on the running line?

Will bulk-packed units with cable leads work on the running line? Check that handling and cable routing match the established assembly before securing E2E-X2F1-5M units for existing production. A mounting or termination change can stall the build even when the sensing specification looks right.

The mounting drawing still has to close the fit

Installed clearance remains unresolved: without the mechanical drawing and target-material correction curve, the listed sensing distance cannot close the fit. The PNP-NO wiring diagram and response-frequency test conditions are also absent; output connection and moving-target timing still need those details.

View the Win-Source product page for E2E-X2F1-5M.

Key Takeaways for Engineers & Buyers

  • Keep E2E-X2F1-5M on sustaining builds and plan migration.
  • Check the 2 mm sensing distance against the installed target path.
  • Match the 10V ~ 40V supply range and PNP-NO, 3-wire output to the existing input.