Omron E2E-X2F2 5M: Discontinued, Sustaining Only

E2E-X2F2 5M Omron product image

2mm sensing, 10V ~ 40V supply limits, threaded M12 body; sustaining designs only.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M12
Core functionSENSOR PROX INDUCTIVE 2MM CYLIND
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 40V

A discontinued sensor is the wrong choice for a new machine

A new machine is the wrong place for E2E-X2F2 5M. It's for sustaining designs where the sensor position and controller input are already established. One lifecycle field says EOL; the lifecycle and product status fields say Discontinued. Either way, a new design-in is out. The part is listed as EU RoHS compliant.

Can the existing line keep its cable-lead build?

Can we secure bulk-packed, cable-lead sensors for the existing line? Keeping that line running means retaining its established wiring and installation process. The PNP-NC, 3-Wire output must match the controller input; a change in logic can leave the machine reading the wrong sensor state. Don't carry this part into a new build; plan migration.

The 2mm reach decides where this M12 sensor belongs

The fit is narrow. A listed 2mm sensing distance puts target clearance first; it says nothing about reliable detection across an unchecked mounting gap. The shielded, threaded M12 inductive sensor belongs at a fixed metal-target position, not wherever a cylindrical sensor happens to fit.

The 10V ~ 40V supply range marks limits, not a preferred working voltage: a rail outside that range rules the part out. The -40°C ~ 85°C operating-temperature range bounds the stated environment, but it does not establish how much margin remains when the sensor is installed inside a heated enclosure. Listed response frequency is 1.5kHz, a starting point for checking machine speed rather than proof the installed target will switch cleanly at that rate. IP67 addresses ingress protection, not a target sitting beyond the 2mm sensing distance.

The M12 body is named; the mounting detail is not

The pinout and dimensional drawing are missing, though the M12 body and cable leads are identified. Get both before changing a panel or wiring a controller. The output load limit and sensing-distance-versus-target-material curve are missing too, leaving controller loading and target tolerance open.

View the Win-Source product page for E2E-X2F2 5M.

Key Takeaways for Engineers & Buyers

  • Check target clearance against the 2mm sensing distance.
  • Match the controller input to the PNP-NC, 3-Wire output.
  • Secure parts for existing production; plan migration from discontinued E2E-X2F2 5M.