Omron E2E-X2F2-M1: Discontinued, for sustaining designs only

E2E-X2F2-M1 Omron product image

2mm sensing ceiling, 10V ~ 40V supply limits, M12 threaded body.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M12
Core functionSENSOR PROX INDUCTIVE 2MM CYLIND
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 40V

M12 fit cannot rescue a discontinued sensor

2mm is the listed sensing-distance ceiling; it doesn't override the lifecycle status. The M12 threaded body remains a fit check on a running line, but E2E-X2F2-M1 belongs in sustaining designs, not a new design-in. One lifecycle signal says EOL while the status fields say Discontinued. Neither supports treating it as Active.

Secure parts for existing production and plan migration before a line depends on further deliveries. Bulk packaging and listed EU RoHS compliance do not change the lifecycle decision.

The rail and target gap set separate boundaries

Supply and clearance limits are independent. A rail inside the listed 10V ~ 40V limits clears only the supply check; it says nothing about the output load the installation can carry, while a rail outside those limits rules out the sensor. The 2mm sensing distance is a ceiling, not a gap to assume under every target condition. If the machine cannot hold the target within that distance, adjusting the controller input will not fix missed detections.

The shielded inductive construction suits a threaded, board-external sensing position where the target passes close to the face. It does not extend the listed reach.

1.5kHz does not specify the switching waveform

1.5kHz is the listed response-frequency ceiling. It screens out an event rate beyond that limit but does not establish the timing of each output transition. A timing calculation needs a response-time figure.

The connector details still block a wiring release

The connector pinout is missing, even though the PNP-NC, 3-Wire output identifies the controller input behavior to plan for. It can't tell an assembler which contact carries each connection. A mechanical drawing is also absent: the M12 thread designation alone cannot settle installed clearance or connector access. Get the pinout and drawing before releasing a replacement cable or mounting arrangement.

The physical details still help screen an industrial sensor position. The body is nickel-plated brass, IP67 is listed, and the operating-temperature range is -40°C ~ 85°C. None establishes the output load limit, which is missing here and matters before selecting the input circuit. E2E-X2F2-M1 can stay in an existing assembly with those interfaces already resolved; a fresh build needs the missing details.

View the Win-Source product page for E2E-X2F2-M1.

Key Takeaways for Engineers & Buyers

  • Keep E2E-X2F2-M1 off new BOMs; secure parts for existing production and plan migration.
  • Check target clearance against the 2mm sensing-distance ceiling.
  • Get the connector pinout before wiring the PNP-NC, 3-Wire output.