2mm sensing distance and 1kHz response frequency in a threaded M8 body.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 2MM PNP M8 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
The short sensing reach is the first design-in test
The 2mm sensing distance and unshielded head leave little room for a casual mechanical swap. The upside: lifecycle fields agree that E2E-X2MB1DL8 5M is Active, so it suits a new design that accommodates its sensing geometry. The threaded M8 stainless-steel body belongs at a machine-mounted detection point, not at a position that needs longer reach.
Its PNP-NO, 3-Wire output needs a matching receiving input. Listed EU RoHS compliance does not settle that electrical fit.
2mm reach matters before 1kHz speed
2mm is the listed sensing-distance limit, not a promise that every target switches at that gap. Target material and fixture tolerance affect repeatability. The 1kHz response-frequency ceiling helps screen moving-target applications, but it does not specify a switching waveform.
Supply and mounting limits narrow the installation
Supply and temperature limits constrain placement: 10V ~ 30V is the operating supply range, and -40°C ~ 85°C is the operating-temperature range. The 30V and 85°C endpoints are ceilings, not preferred settings. A rail outside the stated range or a sensor beyond those temperature bounds is outside the listed conditions.
IP67 and IP69K are listed ingress ratings, but neither settles how the cable exit fits the machine. Without a sensing-distance curve for different targets, an output load-current limit, or a mounting drawing, target clearance and fixture layout remain open, as does input loading.
Will the cable leads fit the line?
Will the cable leads fit the line’s termination method? E2E-X2MB1DL8 5M has cable leads, so settle that question before releasing the BOM. Box is the stated package format; it doesn’t define the connection. A wiring diagram and cable drawing are absent. Get them before committing the harness routing and termination process.
View the Win-Source product page for E2E-X2MB1DL8 5M.
Key Takeaways for Engineers & Buyers
- Set fixture clearance against the 2mm sensing distance; check the actual target.
- Match the PNP-NO, 3-Wire output to the receiving input.
- Check cable-lead termination before committing the M8 installation.