2mm sensing distance, 10V ~ 30V supply limits, M8 body and -40°C ~ 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 2MM PNP M8 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
The 2mm reach puts the mount under scrutiny
Clearance is the constraint: 2mm of sensing distance gives a wandering target little room, while the unshielded M8 body puts metal around the mount in the sensing picture. E2E-X2MB1T8-M1 suits a controlled approach path, not loose mechanics. Test the installed target and mount before counting on the full 2mm.
Keep the supply within the listed 10V ~ 30V limits. The 30V figure is a ceiling, not a preferred setpoint, so check the rail at its worst case. The -40°C ~ 85°C operating range also has a hard upper limit: nearby hot metal does not establish that the sensor stays below 85°C.
Is this Omron sensor still an active ordering choice?
Can buyers still specify it for a new design? Yes. E2E-X2MB1T8-M1 has aligned Active lifecycle signals, with no stated lifecycle reason to migrate a running line. Box is the listed packaging; carry it into the purchase specification. The sensor is EU RoHS compliant.
PNP-NO narrows the controller fit
But Active status doesn't settle the electrical match. The PNP-NO, 3-Wire output belongs on a controller input expecting a sourcing, normally open signal, not a sinking input. The listed 1kHz response frequency is a ceiling; it does not establish that a passing target with a particular dwell time will register.
IP67 and IP69K support a sealed sensor location, but neither establishes the installed connector's sealing. The LED helps with local fault-finding. It cannot correct a mismatched input.
The M8 body is not a wiring drawing
The body is not a wiring drawing. The connector pinout and dimensional drawing are absent, so the M8 thread and connector termination do not settle the mechanical or electrical fit. The output load-current limit and sensing-distance behavior across target metals are also absent. Without those details, the input drive and detection margin remain unresolved.
View the Win-Source product page for E2E-X2MB1T8-M1.
Key Takeaways for Engineers & Buyers
- Test target travel against the listed 2mm sensing distance.
- Keep the supply within the 10V ~ 30V limits.
- Match the controller input to the PNP-NO, 3-Wire output.